Labmate Bench-top Conductivity Meter measures conductivity with range of 0.1 µS/cm to 200 mS/cm. They have large LCD screen that ensures clear readability of results in various environments. Their robust design supports multiple temperature compensation modes for enhanced reliability during testing. They include an automatic calibration function that simplifies setup and operation for operators. Our Bench-top Conductivity Meter are ideal for analyzing water quality in laboratories and industrial settings.
Benchtop Conductivity Meter LMCMB-403 Catalog
| Conductivity Range | 0.000 μS/cm to 199.9 mS/cm |
| Conductivity Resolution | 0.001 μS/cm |
| Conductivity Accuracy | ±0.5 % FS |
| Resistivity Range | 5.00 Ω.cm to 20.00 MΩ.cm |
| Resistivity Resolution | 0.01 Ω.cm |
Benchtop Conductivity Meter LMCMB-402 Catalog
| Conductivity Range | 0.00 μS/cm to 100 mS/cm |
| Conductivity Resolution | 0.01 μS/cm |
| Conductivity Accuracy | ±0.01 FS |
| TDS Range | 0.000 mg/L to 1999 mg/L |
| TDS Resolution | 0.001 mg/L |
Benchtop Conductivity Meter LMCMB-401 Catalog
| Conductivity Range | 0.00 μS/cm to 100 mS/cm |
| Conductivity Resolution | 0.01 μS/cm |
| Conductivity Accuracy | ±0.01 (FS) |
| Power Supply | 100 V to 240 V (50/60Hz) |
| Dimension | 300×220×90 mm |
Benchtop Conductivity Meter LMCMB-404 Catalog
| Conductivity Range | 0.055 μS/cm to 199.9 mS/cm |
| Conductivity Resolution | 0.001 μS/cm |
| Conductivity Accuracy | ±0.5 % FS |
| Resistivity Range | 5.00 Ω.cm to 18.25 MΩ.cm |
| Resistivity Resolution | 0.01 Ω.cm |
Benchtop Conductivity Meter LMCMB-405 Catalog
| Conductivity Range | 0.000 μS/cm to 3000 mS/cm |
| Conductivity Resolution | 0.001 μS/cm |
| Conductivity Accuracy | ±0.5 % FS |
| Resistivity Range | 5.00 Ω.cm to 100 MΩ.cm |
| Resistivity Resolution | 0.01 Ω.cm |
Benchtop Conductivity Meter LMCMB-406 Catalog
| Conductivity mode | 0 to 20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm, ±1% F.S., 0.001, 0.01, 0.1, 1 automatic, 10 µS, 84 µS, 1413 µS, 12.88 mS, 111.8mS, 1, 2, 3 points |
| TDS | 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt, 0.01, 0.1, 1 automatic, ±1% F.S., 0.1 to 1.0 (default 0.5) |
| Temperature | 0 to 105°C/32 to 221°F, 0.1°C/°F, ±1°C/±1.8°F, 1 point, Reading ±10°C/°F |
| Temperature Sensor Accuracy | ±0.1 °C |
| Others | 0 to 100°C/32 to 221°F, manual or automatic, 0.0 to 9.9%/°C, 25°C, K=0.1/1/10/Custom, Manual/Auto-read measurement endpoint, Custom LCD (135 × 75 mm), 6-pin mini-DIN, 3.5mm jack socket, 9V DC power adapter, 220V, 50Hz, 210×205×75mm, 1.5kg |
Benchtop Conductivity Meter LMCMB-407 Catalog
| Conductivity Range | 0 to 3000 mS/cm |
| Conductivity Resolution | 0.001 μS/cm |
| Conductivity Accuracy | ±0.05 |
| Calibration Point | Up to 5 |
| Calibration Reminder | Yes |