Get Quote
Contact us now to receive a detailed quotation.
Automatic Hematology Analyzer processes up to 60 samples per hour providing efficient results quickly. They offer multi-parameter analysis delivering high-quality insights with reliable detection features. Their user-friendly interface supports easy navigation allowing smooth workflow integration. They are built with advanced technology enhancing stability and ensuring dependable operation for clinical laboratories. Our Automatic Hematology Analyzer are ideal for blood sample analysis providing essential data for diagnosis and patient care.
Auto Hematology Analyzer LMHA-A902 Catalog
| Throughput | 60 Samples/Hour |
| Sample Volume | 10 μL |
| Prediluted Mode | 20 μL |
| Storage | Up to 60000 results |
| Reagents | 3 For Test |
Hematology Analyzer LMHA-A901 Catalog
| Principles | Impedance method for RBC and PLT counting Cyanide free reagent for hemoglobin test Flow Cytometry (FCM) + Tri-angle laser scattermethod for WBC 5-part differential analysis and WBC counting |
| Parameters | 27 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym# ,Mon#, Neu#, Eos# , Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-CV, RDW-SD,PLI, MPV, PDW, PCT, LIC%, LIC#, ALY%, ALY# 3 histograms for WBC, RBC and PLT 3 DIFF scatter grams and 1 BASO scatter gram |
| Reagent | DIL-C Diluent, LYC-1 LYSE, LYC-2 LYSE, CLE-P |
| Linearity Range | WBC (0.00-300.00)X 10%/L RBC (0.00-8.50)X1012/L HGB (0-250)G/L PLT (0-3000)X 10%/L HCT 0.0-67.0% |
| Repeatability | WBC≤2.0% RBC≤1.5% HGB≤1.5% PLT≤4.0% MCV≤1.0% |
Automatic Hematology Analyzer LMHA-A1001 Catalog
| Sample Volume | Whole blood: 15µl, Diluted blood: 20µl |
| Throughput | 60 T/H |
| Sample Mode | Whole Blood (Venous/Capillary), Pre-dilution |
| Parameters | 25 Parameters: WBC, LYM%, LYM#, NEU%, NEU#, MON%, MON#, EOS%, EOS#, BAS%, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, P-LCC |
| Accuracy | WBC: Less than or equal to 4.0, RBC: Less than or equal to 2.0, HGB: Less than or equal to 2.0, PLT (103/ µl): Less than or equal to 4.0, MCV: Less than or equal to 3.0 |
Automatic Hematology Analyzer LMHA-A1002 Catalog
| Parameters | 28 Parameters: WBC, LYM%, MON%, NEU%, BAS%, EOS%, LYM#, MON#, NEU#, EOS#, BAS#,RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV,RDW-SD, PLT, MPV, PDW-CV, PDW-SD, PCT,P-LCR, P-LCC, NLR, PLR |
| Performance Precision | 60 samples per hour |
| Sample Volume | 60,000 sample results withscattergrams and histograms |
| Efficiency | 3 Reagent (2 Lyse + 1 Diluent)1 Probe cleanser for maintenance |
| Power Supply | 4 USB ports, 1 LAN port, HL7 protocol, support LIS |
Automatic Hematology Analyzer LMAHA-A100 Catalog
| Measuring Principle | Electro-impedance, photometric analysis |
| Throughput | 60 tests/hr |
| Assay Items | 22 parameters, 3 parts differential of WBC |
| Parameter | WBC, LY, LY%, MO, MO%, GR, GR%, RBC, HGB, HCT, MCV, RDW-SD, RDW-SD, RDW-CV, MCH, MCHC, PLT, MPV, PCT, PDW, WBC histograms, RBC histograms, PLT histograms |
| Sample Volume | 13µl (whole blood), 20µl (prediluted blood) |
Automatic Hematology Analyzer LMAHA-A101 Catalog
| Throughput | 60 samples/hr |
| Sample Volume | ≤20 µl |
| Parameter | Parameter WBC, RBC, HGB, HCT, MCV, MCH, MCHC.RDW-SD, RDW-CV, PLT, MPV, PCT, PDWP-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# |
| Study parameter | ALY%, ALY#, LIC%, LIC# |
| Temperature | 10 to 30℃ |