Get Quote
Contact us now to receive a detailed quotation.
Automated microwave digestion systems break down solid samples in hot acid so metals can be measured afterward. Sealed vessels hold acid and sample under pressure, which speeds digestion and keeps volatile elements from escaping. Models hold 6, 8, 10, 12, 18 or 40 vessels. Most use 100 ml vessels, and the 40 vessel model uses 50 ml vessels. Vessels are made of TFM, a chemical resistant polymer. Maximum temperature is 250 C, and working pressure is 6 MPa. Contactless sensors monitor pressure, and one-direction 360 degree rotation heats samples evenly. A corrosion-proof blower clears fumes. Typical uses include metals testing in food, soil, water and pharmaceutical samples.
Automated Microwave Digestion System LMMDS-A100 Catalog
| Vessel Volume | 100mL |
| Temperature Controlling Range | 50 to 400℃ |
| Max. Working Temperature | 250℃ |
| Temperature Accuracy | ±0.1℃ |
| Pressure Controlling Range | 0 to15MPa |
Automated Microwave Digestion System LMMDS-A101 Catalog
| Vessel Quantity | 6 |
| Vessel Volume | 100mL |
| Cavity Volume | 35L |
| Pressure Monitoring | Contactless pressure sensor |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A102 Catalog
| Vessel Quantity | 8 |
| Vessel Volume | 100mL |
| Cavity Volume | 35L |
| Pressure Monitoring | Contactless pressure sensor |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A103 Catalog
| Vessel Quantity | 10 |
| Vessel Volume | 100mL |
| Cavity Volume | 35L |
| Pressure Monitoring | Contactless pressure sensor |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A104 Catalog
| Vessel Quantity | 6 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A105 Catalog
| Vessel Quantity | 8 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A106 Catalog
| Vessel Quantity | 10 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A107 Catalog
| Vessel Quantity | 12 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A108 Catalog
| Vessel Quantity | 12 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A109 Catalog
| Vessel Quantity | 18 |
| Vessel Volume | 100 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |
Automated Microwave Digestion System LMMDS-A110 Catalog
| Vessel Quantity | 40 |
| Vessel Volume | 50 mL |
| Pressure Monitoring | Contactless pressure sensor |
| Pressure Controlling Range | 0 to 15MPa |
| Maximum Working Pressure | 6MPa |