Automated Cell Counters count, size and classify cells from an image of a stained sample. The software replaces manual hemocytometer counts, which often vary between operators. Brightfield models read trypan blue to tell live cells from dead ones. Fluorescence models use 470, 520 and 620 nm channels for dual-dye viability staining. Each run reports cell concentration and viability. Cell sizes from 0.5 to 200 um are covered, with concentrations up to 3 x 10^7 cells per mL. A count needs 10 to 50 uL of sample and takes up to 90 seconds. Typical uses include cell culture passaging, stem cell work, vaccine production, cytotoxicity testing and yeast counts.
Automated Cell Counter LMACL-B100 Catalog
| Amplification Factor | 2.5 × 5 Megapixel |
| Focusing Method | Auto-focus and auto-exposure, with manual adjustment |
| Sample Volume | 10 µL |
| Cell Counting Area | 2.15 mm × 1.62 mm |
| Diameter Range | 4 to 60 µm |
Automated Cell Counter LMACL-C100 Catalog
| Sample Volume | 10 µL |
| Cell Counting Time | 30 seconds |
| Cell Concentration Range | 5×104 to 1×107 cells/mL |
| Cell Size Range | Detectable Range: 1 to 90 µmOptimal Range: 5 to 60 µm |
| Excitation Wavelength | 470 ± 20 nm |
Automated Cell Counter LMACL-A100 Catalog
| Particle Size Range | 3 to 30µm |
| Sample Volume | 10µL |
| Sample Concentration | 1×10⁴ to 1×10⁷ cells/mL |
| Detection Time | 20 to 30s |
| Data Input and Output | USB 2.0 |
Automated Cell Counter LMACL-A101 Catalog
| Particle Size Range | 3 to 30µm |
| Sample Volume | 10µL |
| Sample Concentration | 1× 10⁴ to 2×10⁷ cells/mL, Maximum at 4×10⁷ cells /mL |
| Detection Time | 20 to 30s |
| Dye | Trypan-blue |
Automated Cell Counter LMACL-A102 Catalog
| Particle Size Range | 3 to 30µm |
| Sample Volume | 10µL |
| Sample Concentration | 1× 10⁴ to 2× 10⁷ cells/mL, Maximum at 4× 10⁷ cells /mL |
| Detection Time | 20 to 30s |
| Dye | Trypan-blue |
Automated Cell Counter LMACL-A103 Catalog
| Particle Size Range | 0.5 to 5µm |
| Sample Volume | 10µL |
| Sample Concentration | 5×10⁴ to 2× 10⁷ cells/mL |
| Detection Time | Less than 90s |
| Data Input and Output | USB 2.0 |
Automated Cell Counter LMACL-A104 Catalog
| Particle Size Range | 10 to 120µm |
| Sample Volume | 20µL/50µL |
| Sample Concentration | 1× 10⁴ to 2 × 10⁶ cells/mL |
| Detection Time | 30 to 60s |
| Data Input and Output | USB 2.0 |
Automated Cell Counter LMACL-A105 Catalog
| Particle Size Range | 3 to 40µm |
| Sample Volume | 30µL |
| Sample Concentration | 2 × 10⁴ to 1 × 10⁷ cells/mL |
| Detection Time | Less than 30s |
| Dual Detection Channels | 620±30nm/520±25nm |
Automated Cell Counter LMACL-C101 Catalog
| Sample Volume | 10 μL or 20 μL |
| Cell Counting Time | Less than 1 second |
| Cell Concentration Range | 1×10⁴ to 3×10⁷ cells/mL |
| Cell Diameter range | 5 to 200μm |
| Viability range | 0 to 100% |