Overview

Atomic Absorption Spectrophotometer LMAAS-A106 features detection limit of less than 0.004 µg/ml for efficient analysis. Integrated with double beam system, it enhances stability and measurement consistency. Incorporates D2 and self-absorption background correction for improved signaling. Equipped with automated acetylene and airflow control, ensuring smooth operation. Our fully PC-controlled system offers advanced and compact design for seamless functionality.

Features :

Titanium alloy self-adjusting burner

Auto-slit selection 

High-performance glass nebulizer

Corrosion-resistant premix chamber

Report printing

Vertical 8-lamp turret

Specifications :

Optical Type Double beam
Atomizer Flame atomizer
Monochromator Czerny-Turner type, focal length at 350mm
Wavelength Range 190 to 900 nm
Wavelength Accuracy ±0.15nm
Wavelength Repeatability ±0.05nm
Grating Holographic diffraction grating with 1800 lines/mm
Slits 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm
Lamp Holder Automated 8 lamp turret
Detector Wide range UV-sensitive photomultiplier tube
Reading Mode Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range 0 to 125%, -0.1 to 3.00A
Static Baseline Drift (Cu) Less than 0.002A/30 min
Dynamic Baseline Drift Less than 0.004A/15min
Background Correction D2 and self-absorption
Characteristic Concentration Cu less than 0.035µg/ml
Detection Limit Cu less than 0.004µg/ml
Repeatability (Cu) RSD less than 0.5%
Acetylene Flow Control Auto 12 level
Air Flow Control Auto 4 level
Burner Head 100mm Titanium alloy burner for air/acetylene operation
Safety Protection Flame sensor, gas leak sensor, gas pressure sensor
Software RGWIN AAS software package
Analytical Method Flame AA, Flame AE, Hydride generation
Concentration Calculation Method Standard curve, Standard Addition, Interpolation
Repeated Measurement Times 1-30 times, Average, SD and RSD
QA/QC Function Correlation coefficient, SD & RSD
Communication Port Standard RS-232
Working Environment Temperature 10-35 °C, Humidity less than 85%
Power Supply 110/220V, 50/60Hz
Dimension(W×D×H) 850×650×550mm
Weight 100KG

Standard Accessories :

Accessory

Unit

Quantity

Main unit

Each

1

Power cable 

Each

1

Data cable

Each

1

Screw driver

Each

1

Cu Hollow cathode lamp

Each

1

Air compressor

Each

1

6mm orange acetylene tube (10m)

Each

1

6mm transparent air tube (10m) 

Each

1

USB (manual and software)

Each

1

Drain tube (2m)

Each

1

Acetylene pressure-reducing valve connector

Each

1

5A fuse

Each

3

Ignition filament

Each

5

Optional Accessories :

Model No

Accessory

Unit

Quantity

LMAAS-A106-H1

Hybrid Generator

Each

1

LMAAS-A106-Q1

Quiet Air Compressor

Each

1

LMAAS-A106-B1

50mm Nitrous Oxide Burner

Each

1

LMAAS-A106-N1

Glass Nebulizer

Each

1

LMAAS-A106-A1

Auto Sampler

Each

1

LMAAS-A106-M1

N2O Module

Each

1

LMAAS-A106-D1

Deuterium Lamp

Each

1

LMAAS-A106-L1

Hollow Cathode Lamp (Al, Ba, Bi, Ca, Co, Cr, Cd, Cu, Fe, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr. Ti, Zr)

Each

1

LMAAS-A106-L2

Hollow Cathode Lamp (Ag, As, Se, Si, Te, V, W)

Each

1

LMAAS-A106-L3

Hollow Cathode Lamp (B, P, Ge, Zr)

Each

1

LMAAS-A106-L4

Hollow Cathode Lamp (Be)

Each

1

LMAAS-A106-L5

Hollow Cathode Lamp (Au)

Each

1

LMAAS-A106-L6

Hollow Cathode Lamp (Rb)

Each

1

LMAAS-A106-L7

Hollow Cathode Lamp (Cs)

Each

1

Applications :

Atomic Absorption Spectrophotometer LMAAS-A106 is ideal for quantifying metal elements in environmental samples, food, pharmaceuticals, biological fluids, mining, agriculture, petrochemicals, and forensic analysis.