Get Quote
Contact us now to receive a detailed quotation.
Overview
Atomic Absorption Spectrophotometer LMAAS-A104 features 190 to 900 nm wavelength range, ensuring broad element detection. Built with single-beam system and flame atomization for efficient analysis. Equipped with automated 4-lamp turret that rotates 360° for stable performance. Incorporates deuterium background correction to minimize spectral interference. Our Spectrophotometer offers flame, gas leak, and pressure sensors for enhanced safety.
Features :
Automated slit selection
High-efficiency glass nebulizer
Automatic up and down burner adjustment
Corrosion-resistant premix chamber
Multiple concentration calculation options
SD and RSD measurements
Parameter and result printing
Specifications :
| Optical Type | Single beam |
| Atomizer | Flame atomizer |
| Monochromator | Czerny-Turner type, focal length at 350mm |
| Wavelength Range | 190 to 900 nm |
| Wavelength Accuracy | ±0.3nm |
| Wavelength Repeatability | ±0.1nm |
| Grating | Holographic diffraction grating with 1800 lines/mm |
| Slits | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0nm |
| Lamp Holder | Automated 4 lamp turret |
| Detector | Wide range UV-sensitive photomultiplier tube |
| Reading Mode | Transmittance(T), Absorbance(A), Concentration(C) |
| Photometric Range | 0 to 125%, -0.1 to 3.00A |
| Static Baseline Drift (Cu) | Less than 0.004A/30 min |
| Dynamic Baseline Drift | Less than 0.006A/15min |
| Background Correction | Deuterium (D2) background correction |
| Characteristic Concentration | Cu less than 0.04µg/ml |
| Detection Limit | Cu less than 0.08µg/ml |
| Repeatability (Cu) | RSD less than 1% |
| Acetylene Flow Control | Auto 12 level |
| Air Flow Control | Auto 4 level |
| Burner Head | 100mm Titanium alloy burner for air/acetylene operation |
| Safety Protection | Flame sensor, gas leak sensor, gas pressure sensor |
| Software | RGWIN AAS software package |
| Analytical Method | Flame AA, Flame AE, Hydride generation |
| Concentration Calculation Method | Standard curve, Standard Addition, Interpolation |
| Repeated Measurement Times | 1-30 times, Average, SD and RSD |
| QA/QC Function | Correlation coefficient, SD & RSD |
| Communication Port | Standard RS-232 |
| Working Environment | Temperature 10-35 °C, Humidity less than 85% |
| Power Supply | 110/220V, 50/60Hz |
| Dimension(W×D×H) | 850×650×550mm |
| Weight | 100KG |
Standard Accessories :
| Accessory | Unit | Quantity |
| Main unit | Each | 1 |
| Power cable | Each | 1 |
| Data cable | Each | 1 |
| Screw driver | Each | 1 |
| Cu Hollow cathode lamp | Each | 1 |
| Air compressor | Each | 1 |
| 6mm orange acetylene tube (10m) | Each | 1 |
| 6mm transparent air tube (10m) | Each | 1 |
| USB (manual and software) | Each | 1 |
| Drain tube (2m) | Each | 1 |
| Acetylene pressure-reducing valve connector | Each | 1 |
| 5A fuse | Each | 3 |
| Ignition filament | Each | 5 |
Optional Accessories :
Model No | Accessory | Unit | Quantity |
LMAAS-A104-H1 | Hybrid Generator | Each | 1 |
LMAAS-A104-Q1 | Quiet Air Compressor | Each | 1 |
LMAAS-A104-B1 | 50mm Nitrous Oxide Burner | Each | 1 |
LMAAS-A104-N1 | Glass Nebulizer | Each | 1 |
LMAAS-A104-A1 | Auto Sampler | Each | 1 |
LMAAS-A104-M1 | N2O Module | Each | 1 |
LMAAS-A104-D1 | Deuterium Lamp | Each | 1 |
LMAAS-A104-L1 | Hollow Cathode Lamp (Al, Ba, Bi, Ca, Co, Cr, Cd, Cu, Fe, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Sr. Ti, Zr) | Each | 1 |
LMAAS-A104-L2 | Hollow Cathode Lamp (Ag, As, Se, Si, Te, V, W) | Each | 1 |
LMAAS-A104-L3 | Hollow Cathode Lamp (B, P, Ge, Zr) | Each | 1 |
LMAAS-A104-L4 | Hollow Cathode Lamp (Be) | Each | 1 |
LMAAS-A104-L5 | Hollow Cathode Lamp (Au) | Each | 1 |
LMAAS-A104-L6 | Hollow Cathode Lamp (Rb) | Each | 1 |
LMAAS-A104-L7 | Hollow Cathode Lamp (Cs) | Each | 1 |
Applications :