Aerodynamic Particle Sizer LMADP-A100

Aerodynamic Particle Sizer LMADP-A100 offers a 7-step system with an additional membrane stage for complete analysis. Incorporated with a 0.5 L/min low-flow rate for optimal aerosol measurement efficiency. It features parameters like Mass Median Aerodynamic Diameter (MMAD) and Geometric Standard Deviation (GSD). Our Aerodynamic Particle Sizer is designed for advanced phase sampling and animal exposure evaluations.

Catalog Send Mail Whatsapp

Specifications

Type Low-flow particle size analyzer
Principle Inertial impact
Sampling Flow Rate 0.5 L /min
Intended Purpose stage sampling, aerosol particle weighing and animal exposure testing
Number of Stages 7 stages + membrane stage
Stage 1 Cutting Diameter 5.1 μm
Stage 2 Cutting Diameter 3.1 μm
Stage 3 Cutting Diameter 1.9 μm
Stage 4 Cutting Diameter 1.2 μm
Stage 5 Cutting Diameter 0.77 μm
Stage 6 Cutting Diameter 0.50 μm
Stage 7 Cutting Diameter 0.33 μm
Calculated Parameters MMAD, GSD

Pricing

Product Price Unit Action
Aerodynamic Particle Sizer LMADP-A100 $ 10937.5 Each of 1

Features

Wide Particle Size Range

High Sensitivity detection

Inertial Impact Mechanism

Low Sample Volume Requirement

Durable Construction

Standard Accessories

Model No.AccessoryUnitQuantity
LMADP-A100-M1Membrane FilterEach1
LMADP-A100-C1Collection PlatesEach7
LMADP-A100-F1Flow Control ValveEach1
LMADP-A100-S1Sample TubingSet1
LMADP-A100-C2Calibration KitSet1
LMADP-A100-C3Cleaning BrushesSet1
LMADP-A100-P1Power CableEach1

Applications

Aerodynamic Particle Sizer LMADP-A100 is ideal for measuring airborne particulates, analyzing aerosol nanoparticles and facilitates inhalation exposure testing in animals for laboratory research.

Selection Guide

Aerodynamic Particle Sizer LMADP-A100 is best suited for research and experiments requiring real-time measurement of airborne particles ranging from airborne particles ranging from 0.5 to 20 microns. Widely applied in aerosol science, environmental monitoring, pharmaceutical aerosol delivery, and filtration studies, it supports applications like inhalation research, cleanroom control, and combustion analysis. Its high-resolution sizing and velocity tracking make it suitable for experiments involving aerosol dynamics, drug delivery systems, and air quality assessments. Apart from the typical applications, its testing range can be tailored to meet specific material and performance requirements, making it a versatile and dependable tool for a wide variety of particle analysis tasks.

Frequently Asked Questions

1 What is an Aerodynamic Particle Sizer LMADP-A100

An Aerodynamic Particle Sizer LMADP-A100 is a low-flow, cascade impactor that measures aerodynamic particle size distribution for aerosol studies in toxicology and environmental monitoring.

2 How does an Aerodynamic Particle Sizer LMADP-A100 work?

An Aerodynamic Particle Sizer LMADP-A100 operates on the principle of inertial impaction, separating particles by their aerodynamic diameter across multiple stages.

3 Can Aerodynamic Particle Sizer LMADP-A100 be used in workplace air quality monitoring?

Aerodynamic Particle Sizer LMADP-A100 evaluates airborne particle size distributions to assess occupational exposure risks.

4 How does Aerodynamic Particle Sizer LMADP-A100 assist in nanomaterial safety research?

Aerodynamic Particle Sizer LMADP-A100 classifies nanoscale particles by aerodynamic size to study potential inhalation hazards.

5 What role does Aerodynamic Particle Sizer LMADP-A100 play in aerosol generator testing?

Aerodynamic Particle Sizer LMADP-A100 verifies the performance and output size distribution of aerosol generators and nebulizers.

6 Why is Aerodynamic Particle Sizer LMADP-A100 important in inhalation toxicology studies?

Aerodynamic Particle Sizer LMPSA-100 helps assess where aerosolized particles deposit in the respiratory tract by providing MMAD and GSD data.

7 Can Aerodynamic Particle Sizer LMADP-A100 help determine deposition sites in animal respiratory tracts?

Aerodynamic Particle Sizer LMADP-A100 predicts deposition zones (nasal, tracheobronchial, alveolar) based on aerodynamic diameter.

8 Can Aerodynamic Particle Sizer LMADP-A100 distinguish between respirable and non-respirable fractions?

Aerodynamic Particle Sizer LMADP-A100 separates particles by aerodynamic size, allowing clear distinction between respirable and non-respirable fractions.

9 Is Aerodynamic Particle Sizer LMADP-A100 compatible with aerosols containing biological agents or pathogens?

Aerodynamic Particle Sizer LMADP-A100 is compatible with biological aerosols when used within appropriate biosafety systems to prevent contamination and exposure.

10 What kind of maintenance does Aerodynamic Particle Sizer LMADP-A100 require?

Routine maintenance includes cleaning of cascade stages, cleaning collection substrates, checking and calibrating flow rates, and periodic inspection of seals to ensure accurate and reliable performance.