Hot Air Oven Overheating And Controller Errors Troubleshooting. blog

Hot Air Oven Overheating And Controller Errors Troubleshooting.

Recent blogs

Double Beam Balance Calibration Adjustment Tips Fixing Zero Errors In Educational And Pharmacy Lab

Double Beam Balance Calibration Adjustment Tips Fixing Zero Errors In Educational And Pharmacy Lab

How a Mechanical Beam Balance Reaches a ReadingA Labmate Double Beam Balance weighs by comparison, not by measuring force. The load tips a beam that pivots on hardened knife edges; known masses and......

Read Blog
Tablet Hardness Tester Inaccurate Results Load Cell Calibration Jaw Alignment Fixes For Pharmacy Lab

Tablet Hardness Tester Inaccurate Results Load Cell Calibration Jaw Alignment Fixes For Pharmacy Lab

What a Crushing Test Measures and Why Units MatterA Labmate Tablet Hardness Tester does not measure hardness in the materials-science sense. It measures the force needed to fracture a tablet pressed......

Read Blog
Liquid Particle Counter Fixing Bubble Interference And Sensor Cleaning

Liquid Particle Counter Fixing Bubble Interference And Sensor Cleaning

How Light Obscuration Counts ParticlesA Labmate liquid particle counter that uses light obscuration passes the sample through a narrow flow cell lit by a laser. Each particle that crosses the beam......

Read Blog
Kjeldahl Analyzer Fixing Low Nitrogen Recovery In Digestion, Distillation And Titration

Kjeldahl Analyzer Fixing Low Nitrogen Recovery In Digestion, Distillation And Titration

The Three Stages Behind a Nitrogen ResultA Labmate Kjeldahl Digestion unit performs only the first of three stages, and a block digestion system of this kind never reports a result by itself. In......

Read Blog
Iodine Meter Maintenance Reagent Handling, And Calibration For Accurate Iodized Salt Quality Testing

Iodine Meter Maintenance Reagent Handling, And Calibration For Accurate Iodized Salt Quality Testing

How an Iodide Electrode Turns a Sample into a ReadingA Labmate Iodine Meter of the ion-selective type, such as the LMIDM-A100, reads the electrical potential that develops across an electrode......

Read Blog
Industrial Ultrasonic Cleaner Troubleshooting Weak Cavitation, Transducer Failure And Tank Erosion

Industrial Ultrasonic Cleaner Troubleshooting Weak Cavitation, Transducer Failure And Tank Erosion

When a Large Tank Stops Cleaning WellA large tank that cleans poorly is an expensive problem, because it holds up production and often goes unnoticed until parts come out dirty. A Labmate Industrial......

Read Blog
Aerodynamic Particle Sizer Maintenance Nozzle Cleaning Size For Aerosol And Inhalation Research

Aerodynamic Particle Sizer Maintenance Nozzle Cleaning Size For Aerosol And Inhalation Research

Two Ways to Size Particles by Aerodynamic DiameterA Labmate Aerodynamic diameter is the diameter of a unit-density sphere that settles at the same speed as the particle being measured, which lets......

Read Blog
Handheld Raman Spectrometer Fluorescence And Library Match Fixes For Pharma ID

Handheld Raman Spectrometer Fluorescence And Library Match Fixes For Pharma ID

What a Handheld Instrument Measures and How It WorksA Labmate Handheld Raman Spectrometer shines a laser onto a sample and analyzes the small fraction of scattered light that has changed color. Each......

Read Blog
Low Temperature Water Bath Cooling, Compressor And Temperature Stability Fixes

Low Temperature Water Bath Cooling, Compressor And Temperature Stability Fixes

How a Refrigerated Bath Holds a SetpointA Labmate Low Temperature Water Bath combines two opposing actions: a compressor-driven refrigeration circuit that removes heat from the bath fluid, and a......

Read Blog
Rectal Thermometer Probe Care And Calibration For Veterinary Research

Rectal Thermometer Probe Care And Calibration For Veterinary Research

What a Rectal Probe Reads and How the Display Is ProducedA Labmate Rectal Thermometer measures temperature deep in the body cavity, where readings follow core temperature more closely than skin,......

Read Blog
Plant Nutrition Analyzer Calibration For Accurate NPK And Micronutrient Readings.

Plant Nutrition Analyzer Calibration For Accurate NPK And Micronutrient Readings.

Why Calibration Decides What a Reading MeansA Labmate Plant Nutrition Analyzer such as the LMPNA-A100 does not weigh nutrients directly. It reports a leaf-level index, and that index becomes......

Read Blog
Automatic Colony Counter Fixing Camera, Lighting And Software Miscounts

Automatic Colony Counter Fixing Camera, Lighting And Software Miscounts

How Image Analysis Turns a Plate into a CountAn Labmate Automatic Colony Counter photographs the agar plate under controlled light, separates colony pixels from the background, splits touching......

Read Blog
Portable Gamma Spectrometer Calibration And Energy Drift Fixes.

Portable Gamma Spectrometer Calibration And Energy Drift Fixes.

Why Spectrum Quality Matters in the FieldA Labmate Portable Gamma Spectrometer LMPGS-A101 does more than count radiation. It records the energy of each gamma ray, which lets it tell one nuclide from......

Read Blog
Freezing Point Osmometer Fixing Supercooling And Osmolality Errors

Freezing Point Osmometer Fixing Supercooling And Osmolality Errors

How Dissolved Particles Lower a Freezing PointThe Labmate Freezing point osmometer's working principle rests on a simple fact: the more particles dissolved in water, the lower its freezing point......

Read Blog
Online Oil Debris Monitor Keeping Ferrous Detection Accurate

Online Oil Debris Monitor Keeping Ferrous Detection Accurate

Why Consistency Matters More Than One NumberA Labmate Ferrous Debris Monitor LMFDM-A100 turns a small oil or grease sample into a number that describes how much ferromagnetic wear debris it carries.......

Read Blog
Handheld XRF Spectrometer Window Replacement And Calibration Checks

Handheld XRF Spectrometer Window Replacement And Calibration Checks

How Fluorescent X-rays Reveal ElementsThe Labmate handheld XRF spectrometer principle is straightforward. An X-ray tube sends primary radiation into the sample, which knocks an inner-shell electron......

Read Blog
Automatic Distillation Apparatus Condenser, Heater And Recovery Fixes

Automatic Distillation Apparatus Condenser, Heater And Recovery Fixes

Why Distillation Faults Rarely Start Where They Show UpAn Automatic Distillation Apparatus LMADA-A100 heats a petroleum sample, condenses the vapor, and measures what is collected, so that the......

Read Blog
HbA1c Analyzer Troubleshooting: Pressure, Calibration And QC Issues

HbA1c Analyzer Troubleshooting: Pressure, Calibration And QC Issues

How the Measurement Is MadeA Labmate Hemoglobin A1C Analyzer reports the share of hemoglobin that has bound glucose, which reflects average blood glucose over the previous two to three months. The......

Read Blog
Seed Analyzer Maintenance Camera Calibration And Imaging Issues

Seed Analyzer Maintenance Camera Calibration And Imaging Issues

How an Imaging Seed Analyzer Reads a SampleUnderstanding how a seed analyzer works makes care routines easier to follow. Seeds are spread on a tray or scanning bed, even lighting removes shadows, and......

Read Blog
Thermal Conductivity Tester Fixing Contact Resistance And Heat Flow Errors

Thermal Conductivity Tester Fixing Contact Resistance And Heat Flow Errors

Why Insulation Readings Drift Without WarningA Labmate Thermal Conductivity Tester LMTCT-A100 reports how well a material carries heat, along with its thermal resistance and thermal diffusivity. For......

Read Blog