Digital Autoclave LMDA-B103 is a 50 L benchtop steam sterilization device that uses high-pressure saturated steam (105–134°C) to sterilize laboratory instruments, glassware, culture media, and consumables.It is used in laboratories, hospitals, and pharmaceutical environments where controlled, repeatable, and higher-capacity sterilization is required.
Model: LMDA-B103
Chamber volume: 50 L
Temperature range: 105–134°C
Pressure range: 0.1–0.25 MPa
Cycle time: 0–120 minutes
Best for: Medium to large laboratory workloads
Key feature: Digital programmable sterilization with monitoring
It sterilizes laboratory materials using pressurized steam to eliminate microorganisms, spores, and biological contaminants.
It is used to sterilize instruments, glassware, media, and laboratory consumables.
Surgical and laboratory instrument sterilization
Culture media and reagent preparation
Glassware sterilization in research labs
Biohazard waste sterilization (small controlled loads)
Cleanroom preparation processes
Labmate LMDA-B103 is suitable for laboratories requiring higher sterilization capacity than mid-range models.
Pharmaceutical production and QA labs
Research and academic institutions
Hospital sterilization departments
Food and microbiology testing laboratories
It uses saturated steam under pressure inside a sealed chamber to achieve sterilization through controlled temperature and time cycles.
Load materials into chamber
Select digital cycle program
Steam increases temperature and pressure
Sterilization phase is maintained
Chamber depressurizes and cools
Sterilized items are removed
Digital programmable sterilization cycles
Real-time monitoring of temperature and pressure
Stainless steel chamber for repeated use
Safety interlock and pressure protection systems
Benchtop configuration for laboratory use
Supports regulated sterilization workflows
Yes. Labmate LMDA-B103 includes programmable liquid cycles that allow sterilization of culture media and liquids without overflow.
Yes. With a 50 L chamber, it supports medium to high workload environments, though very large facilities may require vertical autoclaves.
Overpressure protection system
Door interlock mechanism
Temperature and pressure sensors
Automatic pressure release
Heat-sensitive plastics
Volatile or flammable chemicals
Sealed containers
Electronic components
Biological indicators (spore testing)
Chemical indicators (autoclave tape)
Monitoring of time, temperature, and pressure
Choose Labmate LMDA-B103 when you need higher capacity sterilization with controlled digital operation for medium to large laboratory workloads.
50 L chamber for higher batch processing
Suitable for heavy routine sterilization
Digital monitoring for process consistency
Flexible cycle programming
Choose Labmate LMDA-B103 when:
High sterilization volume is required
Medium to large laboratory throughput is needed
Digital monitoring and compliance tracking are necessary
Space-efficient benchtop design is preferred over vertical units
Regular seal and gasket inspection
Water level monitoring
Periodic calibration checks
Chamber cleaning after use
Supports sterilization practices aligned with:
ISO 17665
Good Laboratory Practice (GLP)
Hospital sterilization protocols