LMDA-B105 For Controlled Decontamination Of Laboratory Instruments And Consumables


What Is Digital Autoclave LMDA-B105?

Digital Autoclave LMDA-B105 is a 70 L high-capacity benchtop steam sterilization system that uses saturated steam (105–134°C) under pressure to sterilize laboratory instruments, glassware, media, and consumables.It is used in laboratories, hospitals, and pharmaceutical environments requiring large-volume, controlled, and repeatable sterilization cycles.

Quick Answer Summary

  • Model: LMDA-B105

  • Chamber volume: 70 L

  • Temperature range: 105–134°C

  • Pressure range: 0.1–0.25 MPa

  • Cycle time: 0–120 minutes

  • Best for: Large laboratory workloads

  • Key feature: Digital programmable sterilization with monitoring

What Does Labmate LMDA-B105 Do?

It sterilizes laboratory materials using high-pressure steam to eliminate microorganisms, spores, and biological contaminants.

What Is This Autoclave Used For?

Direct Answer:

It is used to sterilize instruments, media, glassware, and laboratory consumables at large scale.

Common Applications:

  • Large-scale instrument sterilization

  • Culture media and reagent preparation

  • Glassware sterilization in high-throughput labs

  • Biohazard waste sterilization (controlled loads)

  • Cleanroom and production preparation

Who Should Use Labmate LMDA-B105?

Direct Answer:

Labmate LMDA-B105 is suitable for laboratories requiring high-capacity and continuous sterilization cycles.

Best Fit:

  • Pharmaceutical manufacturing and QA labs

  • Large research institutions

  • Hospital sterilization departments

  • Biotechnology production facilities

  • Food testing laboratories

How Does Labmate LMDA-B105 Work?

Direct Answer:

It uses saturated steam under controlled pressure in a sealed chamber to achieve sterilization through regulated temperature and time cycles.

Process:

  1. Load materials into chamber

  2. Select digital sterilization program

  3. Steam increases pressure and temperature

  4. Sterilization cycle runs for set duration

  5. Chamber depressurizes and cools

  6. Sterilized items are removed

Technical Specifications

Parameter

Specification

Chamber Volume

70 L

Temperature

105–134°C

Pressure

0.1–0.25 MPa

Timer

0–120 minutes

Power

220 V AC, 50 Hz

Dimensions

700 × 600 × 850 mm

Weight

80 kg

Key Features

  • High-capacity 70 L chamber

  • Digital programmable sterilization cycles

  • Real-time monitoring of pressure and temperature

  • Stainless steel corrosion-resistant chamber

  • Safety interlock and overpressure protection

  • Supports regulated laboratory workflows

Can It Sterilize Liquids and Media?

Yes. Labmate LMDA-B105 supports controlled liquid sterilization cycles that prevent boil-over while ensuring complete microbial elimination.

Is Labmate LMDA-B105 Suitable for Large Laboratories?

Yes. It is specifically suited for high-volume laboratory environments requiring continuous sterilization of large batch loads.

What Safety Features Are Included?

  • Overpressure protection system

  • Door interlock mechanism

  • Temperature and pressure sensors

  • Automatic pressure release system

What Materials Cannot Be Sterilized?

  • Heat-sensitive plastics

  • Volatile or flammable chemicals

  • Sealed containers

  • Electronic components

How Is Sterilization Verified?

  • Biological indicators (spore testing)

  • Chemical indicators (autoclave tape)

  • Monitoring of cycle parameters

Why Choose Labmate LMDA-B105 Over Other Models?

Direct Answer:

Choose Labmate LMDA-B105 when high-volume sterilization capacity and continuous laboratory throughput are required.

Key Advantages:

  • Largest chamber in LMDA series (70 L)

  • Suitable for high-demand sterilization workflows

  • Supports batch processing efficiency

  • Digital control for consistent cycle management

Labmate LMDA-B105 vs Other LMDA Models

Model

Capacity

Use Case

LMDA-B100

28 L

Small labs

LMDA-B103

50 L

Medium–large labs

LMDA-B105

70 L

Large labs / high throughput

When Should You Choose This Model?

Choose Labmate LMDA-B105 when:

  • High sterilization volume is required daily

  • Large laboratory or production workflows exist

  • Batch processing efficiency is important

  • Digital monitoring and compliance tracking are required

Maintenance Requirements

  • Regular gasket and seal inspection

  • Water level monitoring

  • Calibration checks

  • Chamber cleaning after cycles

Compliance and Standards

Supports sterilization practices aligned with:

  • ISO 17665

  • Good Laboratory Practice (GLP)

  • Hospital sterilization protocols

Quick Summary

Digital Autoclave LMDA-B105 is a 70 L high-capacity steam sterilizer designed for large-scale laboratory sterilization. It provides programmable digital control and is suitable for high-throughput sterilization in pharmaceutical, hospital, and research environments.