Get Quote
Contact us now to receive a detailed quotation.
An ash content tester is a laboratory instrument used to measure inorganic residue remaining after complete combustion of a sample.
Labmate LMACT-A102 is a bench-top ash content tester used for high-temperature combustion and gravimetric measurement of inorganic residue in laboratory samples.
Measures ash (inorganic residue) after combustion
Uses temperatures up to 1000°C
Based on gravimetric analysis
Supports ASTM, AOAC, and ISO methods
Suitable for food, petroleum, pharma, and environmental testing
Ash testing helps laboratories:
Determine mineral composition
Identify contamination or impurities
Verify product quality and consistency
Support regulatory compliance
Validate formulation accuracy
Labmate LMACT-A102 is used to determine ash percentage by burning off organic matter and measuring the remaining inorganic residue.
Food mineral analysis
Petroleum sulfated ash testing
Pharmaceutical residue analysis
Polymer filler evaluation
Environmental sample testing
It burns the sample and weighs the remaining ash.
Sample placed in crucible
Heated in chamber with controlled temperature
Organic matter decomposes
Inorganic residue remains
Residue weighed to calculate ash percentage
High-temperature combustion chamber
Programmable heating profiles
Uniform heat distribution
Multi-sample batch processing
Gravimetric analysis workflow
Digital interface for monitoring
Food quality laboratories
Petroleum testing labs
Pharmaceutical QC labs
Environmental testing labs
Academic research institutions
Use this instrument when:
Ash content must be measured
Gravimetric methods are required
High-temperature combustion is needed
Multiple samples must be processed
Avoid using it when:
Real-time mass loss tracking is required → use TGA
Only drying or moisture removal is needed → use oven
Simple heating without measurement is sufficient → use furnace
The inorganic residue remains after complete combustion of a material.
A method where results are determined based on weight measurements.
Ash measured after treating a sample with sulfuric acid, commonly used in petroleum testing.
Nutritional mineral testing
Lubricant ash analysis
Pharmaceutical residue evaluation
Polymer composition studies
Environmental inorganic testing
Supports:
ASTM methods
AOAC methods
ISO laboratory protocols
It measures inorganic residue remaining after combustion.
It indicates mineral content, purity, and contamination levels.
Typically 500°C–600°C, but can reach up to 1000°C depending on method.
By dividing residue weight by original sample weight and multiplying by 100.
Usually 1–4 hours depending on sample and method.
An ash tester includes controlled measurement workflow, while a furnace mainly provides heat.
Food, petroleum, pharmaceuticals, polymers, and environmental samples.
Yes, depending on chamber capacity.
Ash Content Testers
Muffle Furnaces
Analytical Balances
Gravimetric Analysis Guide
Laboratory Thermal Equipment