Labmate Portable Steam Sterilizer LMPA-A402


LMPOA-A402 Portable Autoclave – Vertical Steam Sterilizer 

What is LMPOA-A402? 

LMPOA-A402 is a vertical top-loading steam sterilizer used to sterilize laboratory instruments, glassware, culture media, textiles, and biohazard waste using saturated steam at 105–134°C under controlled pressure conditions.

What is LMPOA-A402 used for? 

LMPOA-A402 is used for sterilizing laboratory materials that require high-temperature steam processing. It is commonly used for instruments, glassware, culture media, textiles, and contaminated laboratory waste before disposal.

Who should use LMPOA-A402? 

This model is suitable for:

  • Small to medium laboratories

  • Field and mobile laboratory setups

  • Pharmaceutical QC environments

  • Biotechnology and microbiology labs

  • Veterinary and diagnostic centers

It is selected when compact vertical sterilization is required.

How does LMPOA-A402 work? 

Sterilization occurs through a controlled steam cycle:

  1. Load materials into vertical chamber

  2. Lock lid using mechanical clamps

  3. Heat water to generate saturated steam

  4. Increase temperature to 105–134°C

  5. Build pressure up to 0.1–0.22 MPa

  6. Maintain exposure time for sterilization

  7. Release pressure before chamber opening

What can be sterilized in LMPOA-A402? 

  • Surgical and laboratory instruments

  • Glassware (beakers, flasks, cylinders)

  • Culture media and reagents

  • Laboratory textiles

  • Autoclavable plastics

  • Biohazard waste

What should NOT be sterilized? 

Do not sterilize:

  • Flammable liquids

  • Volatile chemicals

  • Heat-sensitive plastics

  • Reactive chemical substances

Operational Features 

  • Vertical stainless steel chamber

  • Manual timer control system

  • Adjustable temperature settings

  • Pressure gauge monitoring

  • Safety valve system

  • Electric heating system

  • Compact laboratory footprint

  • Heat-resistant handling system

Technical Specifications

Parameter

Specification

Temperature Range

105°C – 134°C

Pressure Range

0.1 – 0.22 MPa

Chamber Type

Vertical Stainless Steel

Control System

Manual Timer

Heating Method

Electric

Power Supply

220V AC

Loading Type

Top-loading

How to choose LMPOA-A402? 

Choose LMPOA-A402 when:

  • Laboratory space is limited

  • Small to medium batch sterilization is required

  • Manual cycle control is acceptable

  • Vertical loading is preferred

Not suitable when:

  • High-volume hospital sterilization is required

  • Fully automated programmable cycles are needed

Comparison Insight

LMPOA-A402 is best suited for compact laboratory environments where moderate sterilization capacity is required. Compared to larger horizontal autoclaves, it provides simpler operation and reduced space requirements, but lower batch throughput.

Typical Applications 

  • Clinical instrument sterilization

  • Microbiology media preparation

  • Laboratory glassware sterilization

  • Biohazard waste decontamination

  • Veterinary laboratory workflows

Compliance Alignment

LMPOA-A402 supports sterilization aligned with:

  • ISO 17665 sterilization standards

  • Good Laboratory Practice (GLP)

  • Clinical laboratory safety protocols

  • Internal QA documentation systems

Step-by-step Maintenance 

  • Clean chamber after use

  • Check gasket condition regularly

  • Inspect pressure valve functionality

  • Ensure proper water level before cycle

  • Use distilled water only

Frequently Asked Questions 

Q1.What is LMPOA-A402?
     It is a vertical steam sterilizer used for laboratory and clinical sterilization of instruments and materials.

Q2. What temperature does it operate at?
       It operates between 105°C and 134°C.

Q3. Can it sterilize liquids?
       Yes, liquid media and reagents can be sterilized using controlled cycles.

Q4. Is it suitable for microbiology labs?
       Yes, it is commonly used in microbiology workflows.

Q5. How long is a sterilization cycle?
       Typically 15–60 minutes depending on load type.

Quick Answer Summary

LMPOA-A402 is a compact vertical autoclave used for sterilizing laboratory instruments, glassware, media, and waste using steam at 105–134°C. It is designed for small to medium laboratory workloads requiring controlled batch sterilization.