LMPOA-A401 is a vertical top-loading portable steam sterilizer used to sterilize laboratory and clinical materials such as instruments, glassware, culture media, textiles, and regulated waste using saturated steam under controlled temperature and pressure.
It is designed for compact laboratory environments and mobile sterilization setups.
LMPOA-A401 is used for:
Sterilizing surgical and laboratory instruments
Processing glassware like beakers and flasks
Sterilizing culture media and reagents
Decontaminating biohazard waste
Sterilizing laboratory textiles and wrapped packs
It works by generating saturated steam inside a sealed chamber. Temperature (105–134°C) and pressure (0.1–0.22 MPa) rise to sterilization levels, destroying microorganisms during a controlled exposure time.
How to use LMPOA-A401:
Load materials into chamber
Lock lid using clamps
Add water and start heating
Steam builds pressure
Maintain sterilization cycle
Release pressure safely
Open after cooling
Temperature: 105°C – 134°C
Pressure: 0.1 – 0.22 MPa
Cycle Time: 15–60 minutes
Capacity: 75–100 L (variant dependent)
Power: 220V AC, 50/60 Hz
Vertical stainless steel chamber
Pressure gauge monitoring
Timer-based sterilization control
Safety valve system
Heat insulated handles
Electric heating system
LMPOA-A401 performs:
Moist heat sterilization
Microbial and spore destruction
Batch sterilization of lab loads
SOP-based sterilization support
Use this sterilizer when:
Laboratory space is limited
Mobile or field sterilization is required
Medium batch sterilization is needed
Vertical loading workflow is preferred
Do not use for:
Flammable substances
Volatile chemicals
Heat-sensitive materials
Non-autoclavable plastics
Pharmaceutical labs
Biotechnology research centers
Clinical diagnostic labs
Veterinary clinics
Academic institutions
Environmental labs
LMPOA-A401 vs Benchtop Autoclave:
LMPOA-A401 → Better for mobile + vertical sterilization workflow
Benchtop autoclave → Better for fixed countertop use
Q1: What is LMPOA-A401 used for?
A: It is used for steam sterilization of laboratory instruments, glassware, culture media, and waste.
Q2: What is the temperature range?
A: It operates between 105°C and 134°C.
Q3: How long is the sterilization cycle?
A: Typically 15–60 minutes depending on load type.
Q4: What is chamber capacity?
A: 75–100 liters depending on variant.
Q5: Can it sterilize liquids?
A: Yes, culture media and aqueous reagents can be sterilized.
Q6: Is it suitable for field labs?
A: Yes, it supports mobile and decentralized use.
LMPOA-A401 supports:
ISO 17665 sterilization standard
Good Laboratory Practice (GLP)
Laboratory quality documentation systems