LMPOA-A400 is a vertical top-loading steam sterilizer used to sterilize laboratory instruments, glassware, culture media, textiles, and biohazard waste. It operates using saturated steam under controlled temperature (105–134°C) and pressure (0.1–0.22 MPa), enabling microbial inactivation in laboratory and clinical environments.
LMPOA-A400 is used for sterilizing laboratory materials that require high-temperature steam processing. It is commonly used for surgical instruments, glassware, culture media, textiles, and contaminated laboratory waste before disposal.
This autoclave is suitable for:
Pharmaceutical QC laboratories
Biotechnology and microbiology labs
Clinical diagnostic centers
Veterinary laboratories
Academic research facilities
Field and mobile laboratories
It is selected when compact vertical sterilization is required in limited-space environments.
Sterilization occurs in a controlled steam cycle:
Materials are loaded into the vertical chamber
Lid is locked using mechanical clamps
Water is heated electrically to produce saturated steam
Temperature rises to 105–134°C
Pressure increases to 0.1–0.22 MPa
Load is exposed for a defined time cycle
Controlled pressure release is completed before opening
LMPOA-A400 can sterilize:
Metal instruments
Glassware (flasks, beakers, cylinders)
Culture media and reagents
Laboratory textiles
Autoclavable plastics
Biohazard waste
Vertical stainless steel chamber
Timer-based sterilization control
Adjustable temperature settings
Pressure gauge monitoring system
Safety valve for pressure release
Electric heating system
Compact vertical footprint
Heat-resistant handles
Choose LMPOA-A400 when:
Laboratory space is limited
Small to medium batch sterilization is required
Manual cycle control is acceptable
Vertical loading is preferred over front-loading systems
If higher volume processing is required, horizontal or large vertical autoclaves are more suitable.
LMPOA-A400 includes:
Mechanical lid locking system
Pressure release valve
Overpressure protection system
It should not be used for flammable, volatile, or heat-sensitive materials.
Clinical instrument sterilization
Microbiology media preparation
Laboratory glassware sterilization
Biohazard waste decontamination
Veterinary diagnostic sterilization workflows
LMPOA-A400 supports sterilization practices aligned with:
ISO 17665 sterilization standards
Good Laboratory Practice (GLP)
Clinical laboratory sterilization protocols
Internal QA documentation systems
Compared to benchtop autoclaves, LMPOA-A400 provides:
Higher chamber capacity than small tabletop units
Better portability than horizontal autoclaves
Manual control instead of programmable automation
Suitable balance between space and capacity
Q1. What is LMPOA-A400?
It is a vertical steam sterilizer used for laboratory and clinical sterilization of instruments, media, and waste.
Q2. What is the sterilization temperature range?
It operates between 105°C and 134°C depending on cycle settings.
Q3. Can it sterilize liquids?
Yes, liquid culture media and reagents can be sterilized using controlled exposure cycles.
Q4. Is it suitable for microbiology labs?
Yes, it is widely used for microbiology sterilization workflows.
Q5. Does it support laboratory compliance documentation?
Yes, cycle parameters can be recorded for quality documentation.