Get Quote
Contact us now to receive a detailed quotation.
LMPOA-A300 is a vertical, top-loading portable steam sterilizer used to sterilize laboratory instruments, glassware, culture media, textiles, and biohazard waste using saturated steam at 105°C–134°C under controlled pressure.
It is used in laboratories, clinics, and field environments where compact sterilization systems are required.
A portable steam sterilizer is a compact autoclave that uses pressurized saturated steam to eliminate microorganisms from laboratory materials. It works by exposing materials to high temperature and pressure for a defined sterilization cycle.
LMPOA-A300 is used for sterilizing laboratory and clinical materials such as:
Surgical and laboratory instruments
Glassware (flasks, beakers, cylinders)
Culture media and reagents
Wrapped instrument packs
Laboratory textiles
Biohazard and microbiology waste
Materials are loaded into the vertical stainless steel chamber
Lid is locked using mechanical clamps
Water is heated electrically to generate steam
Steam builds pressure inside the chamber
Sterilization cycle runs at 105°C–134°C
Load is held for microbial inactivation time
Pressure is safely released before opening
Temperature range: 105°C to 134°C
Pressure range: 0.1 to 0.22 MPa
These parameters are used for microbial and spore inactivation in laboratory sterilization workflows.
A typical cycle takes 15 to 60 minutes, depending on:
Load type
Temperature selected
Material density
Cooling time is additional.
Pharmaceutical laboratories
Biotechnology and microbiology labs
Clinical and diagnostic centers
Veterinary clinics
Academic research institutions
Environmental testing laboratories
Vertical stainless steel chamber
Timer-based cycle control
Pressure gauge monitoring
Safety valve for pressure release
Electric heating system
Compact portable design
Heat-resistant handling system
Choose this model when:
Laboratory space is limited
Small to medium sterilization batches are required
Vertical loading workflow is preferred
Manual cycle control is acceptable
Portable sterilization setup is needed
Yes. It can sterilize:
Culture media
Aqueous reagents
Laboratory liquids
Using controlled steam exposure cycles.
Yes. It is used in:
Clinical laboratories
Veterinary clinics
Diagnostic centers
Field medical setups
Pressure safety valve
Lid locking system (prevents opening under pressure)
Controlled steam exhaust system
Over-temperature protection
ISO 17665 (Sterilization of healthcare products)
GLP (Good Laboratory Practice)
Laboratory SOP compliance systems
Clinical sterilization documentation practices
Choose LMPOA-A300 → for compact lab sterilization
Choose Horizontal autoclave → for high-volume processing
Choose Benchtop autoclave → for small desktop use
It is used for sterilizing lab instruments, glassware, media, textiles, and waste using steam pressure.
Yes, it can process regulated laboratory biohazard waste.
Yes, it is designed for compact and mobile laboratory setups.
Minimal setup is required; it operates on standard electrical supply.
Yes, it is widely used in microbiology workflows.