LMPA-A201 is a vertical, top-loading portable steam sterilizer used to sterilize laboratory instruments, glassware, culture media, textiles, and regulated waste using high-temperature saturated steam under controlled pressure conditions.
It is used in laboratory, clinical, and field environments where compact sterilization capacity is required.
LMPA-A201 is used for sterilizing:
Surgical and laboratory instruments
Glassware such as flasks and cylinders
Culture media and reagents
Laboratory textiles and wrapped packs
Biohazard waste before disposal
It works by generating saturated steam inside a sealed chamber where temperature and pressure rise to sterilization levels. Microorganisms are destroyed during a controlled exposure time, followed by safe pressure release before opening.
How to operate LMPA-A201:
Load items into the vertical chamber
Lock the lid using clamps
Heat water to generate saturated steam
Allow pressure and temperature to reach set level
Maintain exposure time for sterilization
Release pressure in a controlled manner
Open chamber after safe cooling
Stainless steel vertical chamber
Adjustable temperature control
Pressure monitoring gauge
Timer-based cycle control
Safety valve for pressure release
Electric heating system
Compact portable structure
Heat insulated handles
LMPA-A201 performs:
Sterilization of solid and liquid lab materials
Destruction of microorganisms and spores
Batch processing of laboratory loads
SOP-based sterilization documentation support
Temperature Range: 105°C – 134°C
Pressure Range: 0.1 – 0.22 MPa
Chamber Type: Vertical stainless steel
Control System: Manual timer-based
Power Supply: 220V AC, 50/60 Hz
Use this sterilizer when:
Space in laboratory is limited
Mobile or field sterilization is required
Batch sterilization is performed frequently
Vertical loading is preferred workflow
Do not use it for:
Flammable materials
Volatile chemicals
Heat-sensitive plastics
Materials incompatible with steam sterilization
LMPA-A201 vs Benchtop Autoclave:
LMPA-A201: better for mobile and vertical loading workflows
Benchtop autoclave: better for fixed countertop use
Pharmaceutical laboratories
Biotechnology research centers
Clinical diagnostic labs
Veterinary hospitals
Academic institutions
Environmental testing labs
Q1: What is LMPA-A201 used for?
A: It is used for steam sterilization of laboratory instruments, glassware, media, textiles, and waste.
Q2: What temperature does it operate at?
A: It operates between 105°C and 134°C depending on cycle settings.
Q3: Can it sterilize liquid media?
A: Yes, liquid culture media and reagents can be sterilized.
Q5: How long is a sterilization cycle?
A: Typically 15–60 minutes depending on load and temperature.
Q7: Is it suitable for field laboratories?
A: Yes, its compact vertical design supports mobile and field use.
LMPA-A201 supports:
ISO 17665 sterilization practices
Good Laboratory Practice (GLP)
Laboratory quality documentation systems