It eliminates microorganisms, bacterial spores, and contaminants from laboratory materials using high-temperature saturated steam under controlled pressure cycles.
LMPA-A200 is used for:
Sterilizing surgical and laboratory instruments
Processing culture media and liquid reagents
Sterilizing glassware such as flasks and cylinders
Decontaminating laboratory textiles and wraps
Treating biohazard waste before disposal
It is suitable for:
Pharmaceutical QC laboratories
Biotechnology and microbiology labs
Clinical and diagnostic centers
Veterinary laboratories
Academic research labs
Field and mobile testing units
It is selected when space is limited and batch sterilization is required.
Materials are loaded into a vertical stainless steel chamber
Lid is locked using mechanical clamps
Water is heated to produce saturated steam
Pressure and temperature rise to set parameters
Load is maintained for sterilization exposure time
Controlled depressurization occurs
Chamber is opened after safe pressure release
Temperature range: 105°C – 134°C
Pressure range: 0.1 – 0.22 MPa
Cycle time: 15–60 minutes (based on load type)
Control system: Manual timer-based
Heating: Electric
Chamber type: Vertical stainless steel
Yes. It sterilizes liquid culture media and aqueous laboratory reagents using controlled exposure time and pressure cycles.
Yes. It is commonly used in microbiology laboratories for sterilizing tools, media, and contaminated materials.
Vertical stainless steel chamber
Timer-based cycle control
Pressure gauge monitoring
Safety valve for pressure release
Electric heating system
Heat-insulated handling system
Compact portable structure
Choose this model when:
Vertical loading is preferred
Laboratory has limited floor space
Moderate batch sterilization is required
Manual cycle control is acceptable
Field or mobile usage is needed
Do not use LMPA-A200 for:
Flammable materials
Volatile chemicals
Heat-sensitive instruments
Materials incompatible with moisture or high pressure
Pharmaceutical research and QC labs
Biotechnology research facilities
Clinical diagnostic laboratories
Veterinary hospitals
Academic institutions
Environmental monitoring labs
LMPA-A200 is preferred over:
Benchtop autoclaves → when mobility and vertical loading are needed
Horizontal autoclaves → when space saving is prioritized
Dry heat sterilizers → when moisture-based sterilization is required
Supports sterilization workflows aligned with:
ISO 17665 sterilization standards
Good Laboratory Practice (GLP)
Clinical laboratory quality systems
Internal SOP documentation systems
Q1. What is the main purpose of LMPA-A200?
It is used to sterilize laboratory instruments and materials using pressurized steam.
Q2. What temperature does it operate at?
It operates between 105°C and 134°C.
Q3. Can it sterilize liquids?
Yes, it can sterilize culture media and aqueous systems.
Q4. How long is a sterilization cycle?
Typically 15 to 60 minutes depending on load.
Q5. Is it safe to use?
Yes, it includes pressure control valves and locking mechanisms to prevent accidental opening.