LMPOA-A101 is a vertical top-loading portable steam sterilizer used in laboratories and clinical environments to sterilize instruments, glassware, culture media, textiles, and biohazard waste using saturated steam under controlled temperature and pressure.
It is designed for compact laboratories, field setups, and decentralized sterilization workflows.
LMPOA-A101 is used for:
Sterilizing surgical and lab instruments
Processing glassware (flasks, beakers, cylinders)
Sterilizing culture media and reagents
Treating laboratory textiles
Decontaminating biohazard waste
It works by generating saturated steam inside a sealed stainless steel chamber. Temperature (105–134°C) and pressure (0.1–0.22 MPa) rise to sterilization levels, killing microorganisms during a controlled exposure time.
How to use LMPOA-A101:
Load items into chamber
Lock lid using clamps
Add water and start heating
Steam builds pressure and temperature
Maintain sterilization cycle time
Release pressure safely
Open after cooling
Temperature: 105°C – 134°C
Pressure: 0.1 – 0.22 MPa
Cycle Time: 15–60 minutes
Chamber Type: Vertical stainless steel
Power: 220V AC, 50/60 Hz
Vertical stainless steel chamber
Timer-controlled cycles
Pressure gauge monitoring
Safety valve system
Heat insulated handles
Electric heating system
LMPOA-A101 performs:
Moist heat sterilization
Microbial and spore destruction
Batch sterilization of lab loads
SOP-based sterilization support
Use this sterilizer when:
Laboratory space is limited
Mobile sterilization is required
Medium batch sterilization is needed
Vertical loading workflow is preferred
Do not use for:
Flammable materials
Volatile chemicals
Heat-sensitive plastics
Non-autoclavable substances
Pharmaceutical laboratories
Biotechnology research labs
Clinical diagnostic centers
Veterinary clinics
Academic institutions
Environmental labs
LMPOA-A101 vs Benchtop Autoclave:
LMPOA-A101 → Better for mobile + vertical workflow
Benchtop → Better for fixed countertop usage
Q1: What is LMPOA-A101 used for?
A: It is used for steam sterilization of laboratory instruments, glassware, media, and waste.
Q2: What is the temperature range?
A: It operates between 105°C and 134°C.
Q3: How long is the sterilization cycle?
A: Typically 15–60 minutes depending on load.
Q4: Can it sterilize liquids?
A: Yes, culture media and aqueous systems can be sterilized.
Q5: Is it suitable for field labs?
A: Yes, its compact vertical design supports field use.
LMPOA-A101 supports:
ISO 17665 sterilization standard
Good Laboratory Practice (GLP)
Laboratory quality documentation systems