LMPA-A100 is a vertical, top-loading portable pressure steam sterilizer used to sterilize laboratory instruments, glassware, culture media, textiles, and regulated waste using saturated steam at 105°C–134°C under controlled pressure (0.1–0.22 MPa).
It is used in laboratory, clinical, and field environments where compact sterilization capacity is required.
It removes microorganisms, bacterial spores, and contaminants from laboratory materials using high-temperature steam and pressure cycles.
It is used to ensure laboratory materials are safe, contamination-free, and suitable for reuse or disposal in regulated environments.
Load materials into vertical stainless steel chamber
Lock lid using mechanical clamps
Heat water to generate saturated steam
Pressure and temperature rise to sterilization levels
Maintain exposure time for microbial inactivation
Controlled pressure release before opening
Safe removal of sterilized load
It can sterilize:
Surgical and laboratory instruments
Glassware (flasks, cylinders, beakers)
Culture media and liquid reagents
Laboratory textiles and wrapped packs
Biohazard laboratory waste
It is suitable for:
Pharmaceutical laboratories
Biotechnology and microbiology labs
Clinical diagnostic centers
Veterinary hospitals
Academic research institutions
Field and mobile laboratories
Temperature range: 105°C – 134°C
Pressure range: 0.1 – 0.22 MPa
Cycle time: 15–60 minutes (depends on load)
Heating method: Electric
Control system: Manual timer-based
Chamber type: Vertical stainless steel
Yes, it sterilizes culture media and aqueous laboratory systems using controlled steam exposure cycles.
Yes, it is widely used in microbiology laboratories for sterilizing tools, media, and contaminated materials.
Vertical stainless steel chamber
Timer-controlled sterilization cycles
Pressure gauge monitoring
Safety valve system
Mechanical lid locking system
Electric heating system
Compact portable design
Heat-insulated handles
Use LMPA-A100 when:
Vertical loading is required
Laboratory space is limited
Moderate batch sterilization is needed
Mobile or field usage is required
Manual cycle control is acceptable
Do not use LMPA-A100 for:
Flammable chemicals
Volatile substances
Heat-sensitive laboratory materials
Non-steam compatible equipment
LMPA-A100 is preferred over:
Benchtop autoclaves → when portability is required
Horizontal autoclaves → when space efficiency is needed
Dry heat sterilizers → when moisture-based sterilization is required
Typical cycle duration ranges from 15 to 60 minutes depending on load type and sterilization temperature.
Supports sterilization systems aligned with:
ISO 17665 sterilization standards
Good Laboratory Practice (GLP)
Clinical laboratory protocols
Internal SOP documentation systems
Q1. What is the purpose of LMPA-A100?
It is used to sterilize laboratory instruments and materials using steam under pressure.
Q2. What temperature does it operate at?
It operates between 105°C and 134°C.
Q3.Can it sterilize liquids?
Yes, it can sterilize culture media and aqueous systems.
Q4. Is it safe to use?
Yes, it includes pressure safety valves and locking mechanisms.
Q5. Can it be used in field laboratories?
Yes, its compact design supports mobile and decentralized lab environments.