Get Quote
Contact us now to receive a detailed quotation.
LMPSS-A101 is a vertical portable pressure steam sterilizer used in laboratory and clinical environments. It sterilizes glassware, instruments, and laboratory containers using saturated steam at approximately 126°C under 0.14–0.16 MPa pressure. It supports small-scale sterilization workflows in microbiology, clinical labs, and field laboratory setups.
A pressure steam sterilizer is used to eliminate microorganisms using high-temperature saturated steam under pressure.
Sterilizing laboratory glassware and flasks
Decontaminating culture media containers
Sterilizing metal laboratory instruments
Processing reusable lab consumables
Supporting microbiology and tissue culture workflows
Pre-treatment of laboratory waste before disposal
Water is heated inside a sealed stainless steel chamber
Steam builds pressure up to 0.14–0.16 MPa
Temperature reaches approximately 126°C
Materials inside are exposed to saturated steam
Microorganisms are destroyed through moist heat
Cycle is maintained for a defined time
Pressure is released before safe unloading
Temperature: ~126°C
Working Pressure: 0.14 – 0.16 MPa
Safety Pressure Limit: 0.165 MPa
Chamber Capacity: ~18 Liters
Sterilizing Volume: φ280 × 260 mm
Yes. It is commonly used in microbiology laboratories for:
Culture media sterilization
Glassware preparation
Instrument decontamination
Laboratory waste processing
Typical cycle time: 15 to 45 minutes
(depending on load size and material type)
Suitable materials include:
Glassware (flasks, bottles, beakers)
Metal laboratory instruments
Autoclavable plastic containers
Laboratory media vessels
Not suitable for:
Heat-sensitive plastics
Flammable or volatile materials
Vertical stainless steel chamber
Manual pressure control system
Integrated pressure gauge
Mechanical lid locking system
Electric heating system (optional LPG in some variants)
Compact laboratory footprint
Choose this sterilizer when:
You need small-scale sterilization
Laboratory space is limited
Manual control is acceptable
Pressure monitoring is required
Field or mobile lab usage is needed
Yes. Safety is maintained through:
Pressure release valve
Locking lid mechanism
Real-time pressure monitoring gauge
Controlled exhaust system
Yes. The compact structure supports:
Mobile labs
Temporary field setups
Decentralized sterilization units
Routine maintenance includes:
Cleaning chamber after cycles
Checking gasket and sealing ring
Inspecting pressure gauge function
Ensuring valve safety operation
Using distilled water to reduce scaling
LMPSS-A101 is used in workflows aligned with:
Moist heat sterilization protocols
Laboratory SOP systems
Contamination control standards
General microbiology and clinical lab hygiene practices
Benchtop autoclaves → higher capacity labs
Electric sterilizers → automated control environments
Dry heat sterilizers → moisture-sensitive materials
Portable autoclaves → advanced cycle automation
LMPSS-A101 is best for small laboratory sterilization needs
Benchtop autoclaves are better for higher volume processing
Portable units offer better mobility, but lower batch capacity
It is used for sterilizing laboratory glassware, instruments, and culture media using pressurized steam.
Approximately 126°C under controlled pressure conditions.
Yes, laboratory media and aqueous systems can be sterilized using proper cycle settings.
Yes, it is designed for portable and decentralized laboratory environments.
Distilled or deionized water is recommended to prevent scaling.