LMLS-A901 is a vertical, top-loading pressure steam sterilizer that uses saturated steam at 105°C–134°C under controlled pressure to sterilize laboratory instruments, glassware, culture media, textiles, and biohazard waste.
It is used in laboratories where controlled microbial inactivation and batch sterilization are required.
A pressure steam sterilizer is a device that uses high-temperature steam under pressure to destroy microorganisms such as bacteria, viruses, and spores on laboratory materials.
It works by combining heat, moisture, and pressure to achieve sterilization.
LMLS-A901 is used for sterilizing:
Laboratory and surgical instruments
Glassware (flasks, beakers, cylinders)
Culture media and reagents
Wrapped instrument packs
Laboratory textiles
Biohazard and microbial waste
It is used in laboratory, clinical, veterinary, and research environments.
Load materials into vertical stainless steel chamber
Lock lid using mechanical clamps
Heat water to generate saturated steam
Increase temperature to 105°C–134°C
Build pressure up to 0.1–0.22 MPa
Maintain exposure time for sterilization
Release pressure safely
Open chamber after cooling
This process kills microorganisms using moist heat and pressure.
It is suitable for:
Pharmaceutical laboratories
Microbiology and biotechnology labs
Clinical diagnostic labs
Veterinary clinics
Academic research labs
Field laboratories
Use LMLS-A901 when:
You need small to moderate batch sterilization
Laboratory space is limited
Portable sterilization is required
Manual cycle control is acceptable
Steam sterilization is required for mixed materials
Metal instruments
Glassware
Culture media
Textiles
Biohazard waste
Flammable liquids
Volatile chemicals
Heat-sensitive plastics
Choose this model if:
Vertical loading is preferred
Compact footprint is required
Batch sterilization is done daily
Manual timer control is sufficient
Temperature range: 105°C–134°C
Pressure range: 0.1–0.22 MPa
Chamber type: Vertical stainless steel
Control: Manual timer
Power: 220 V AC, 50/60 Hz
Loading: Top-loading
Pressure release valve
Mechanical lid lock
Over-temperature protection
Controlled depressurization system
A standard sterilization cycle takes 15–60 minutes depending on load type, followed by cooling time.
Yes. It sterilizes biological waste using high-temperature steam before safe disposal.
It is used for sterilizing laboratory instruments, media, and biohazard waste using steam under pressure.
It operates between 105°C and 134°C.
Yes. It sterilizes culture, media and aqueous systems.
Yes. It is commonly used in microbiology sterilization workflows.
Yes. It is designed for portable and decentralized use.
Use LMLS-A901 when:
You need portability → yes
You need high-volume sterilization → no
You need simple manual operation → yes
You need cleanroom integration → limited use
Supports sterilization practices aligned with:
ISO 17665
Good Laboratory Practice (GLP)
Laboratory QA documentation standards