LMSE-A101 is a compact vertical electric steam sterilizer used to sterilize laboratory glassware, culture vessels, and small lab equipment using pressurized steam at 126°C under controlled pressure conditions.
LMSE-A101 sterilizes laboratory materials using moist heat under pressure. It is used to eliminate microbial contamination from glassware, media containers, and lab instruments in research and clinical environments.
Laboratories use LMSE-A101 to ensure contamination-free glassware and culture vessels. It supports sterilization workflows where small batch processing and controlled steam exposure are required for microbiology, tissue culture, and research applications.
This sterilizer is suitable for:
Academic laboratories
Biotechnology and microbiology labs
Pharmaceutical QC environments
Clinical diagnostic labs
Field and mobile laboratory setups
It is selected when compact 18L steam sterilization is required.
Sterilization occurs in a controlled steam cycle:
Load labware into 18L chamber
Close and lock lid securely
Heat water to generate saturated steam
Reach operating temperature (~126°C)
Build pressure (0.14–0.16 MPa)
Maintain sterilization time cycle
Release pressure safely before opening
Glass flasks and beakers
Culture vessels and media bottles
Metal laboratory instruments
Autoclavable plastics
Laboratory tools used in microbiology
Do NOT use LMSE-A101 for:
Flammable liquids
Volatile chemicals
Heat-sensitive plastics
Non-autoclavable materials
18L stainless steel chamber
Integrated pressure gauge
Secure mechanical locking system
Electric heating system (LPG optional)
Compact bench-top design
Real-time pressure monitoring
Heat-resistant handling structure
Choose LMSE-A101 when:
Laboratory space is limited
Small batch sterilization is required
Glassware and media containers are primary load types
Manual cycle control is acceptable
Not suitable when:
Large hospital-scale sterilization is required
High automation or programmable cycles are needed
Fill chamber with distilled water
Load compatible glassware
Lock lid securely
Set temperature and time cycle
Start electric heating cycle
Monitor pressure gauge
Allow controlled cooling before opening
Clean chamber after each cycle
Inspect gasket and sealing ring regularly
Check pressure gauge accuracy
Use only distilled water
Ensure valve safety inspection periodically
Microbiology media preparation
Glassware sterilization in labs
Tissue culture workflow support
Pharmaceutical QC sterilization tasks
Field laboratory sterilization setups
LMSE-A101 supports sterilization workflows aligned with:
Laboratory SOP documentation practices
Microbiology lab hygiene protocols
General sterilization safety standards
LMSE-A101 is best suited for small laboratory sterilization tasks requiring 18L capacity. Compared to larger autoclaves, it offers compact size and simpler operation, but lower throughput capacity.
Q1.What is LMSE-A101?
It is a compact electric steam sterilizer used for laboratory glassware and instrument sterilization.
Q2. What temperature does it operate at?
It operates at approximately 126°C.
Q3.What is the chamber capacity?
It has an 18L stainless steel chamber.
Q4. Can it sterilize liquids?
Yes, culture media and laboratory reagents can be sterilized.
Q5. Is it suitable for microbiology labs?
Yes, it is widely used in microbiology workflows.
Q6.What is the cycle time?
Typically 15–45 minutes depending on load type.