Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Labmate Portable Autoclave LMPOA-A109


Portable Autoclave LMPOA-A109 – Vertical Steam Sterilization Unit

What is LMPOA-A109 Portable Autoclave?

LMPOA-A109 is a vertical top-loading portable steam autoclave used for sterilizing laboratory instruments, glassware, culture media, textiles, and biohazard waste. It operates using saturated steam at 105°C–134°C under controlled pressure to achieve microbial inactivation in laboratory, clinical, and field environments.

What is a Portable Autoclave Used For?

A portable autoclave is used to sterilize laboratory and clinical materials using steam under pressure.

LMPOA-A109 is used for:

  • Sterilization of surgical instruments

  • Glassware used in microbiology labs

  • Culture media and reagents

  • Laboratory textiles and dressings

  • Biohazard waste decontamination

How Does LMPOA-A109 Work? 

  1. Materials are placed in the vertical chamber

  2. Lid is sealed using mechanical locking clamps

  3. Water is heated to generate saturated steam

  4. Pressure rises to sterilization level (0.1–0.22 MPa)

  5. Temperature is maintained between 105°C–134°C

  6. Exposure time is completed for microbial destruction

  7. Pressure is released safely before opening

Where is LMPOA-A109 Used?

LMPOA-A109 is used in:

  • Pharmaceutical laboratories

  • Biotechnology research labs

  • Clinical diagnostic centers

  • Veterinary clinics

  • Academic institutions

  • Field and mobile laboratories

What Temperature Does LMPOA-A109 Use?

The system operates at:

  • Temperature: 105°C to 134°C

  • Pressure: 0.1 to 0.22 MPa

These parameters vary based on load type and sterilization cycle.

Can LMPOA-A109 Sterilize Biohazard Waste?

Yes. It sterilizes laboratory biohazard waste using steam treatment before disposal. This reduces microbial contamination risk in laboratory environments.

Key Features of LMPOA-A109

  • Vertical stainless steel chamber

  • Manual timer-based control system

  • Pressure gauge monitoring

  • Safety valve for pressure control

  • Electric heating system

  • Compact portable design

  • Heat-insulated handles

Technical Specifications

Parameter

Specification

Temperature Range

105°C – 134°C

Pressure Range

0.1 – 0.22 MPa

Chamber Type

Vertical Stainless Steel

Control System

Manual Timer

Power Supply

220 V AC, 50/60 Hz

Application

Laboratory & Clinical Sterilization

How to Select LMPOA-A109

This model is suitable when:

  • Laboratory space is limited

  • Portable sterilization is required

  • Small to medium batch sterilization is needed

  • Manual cycle control is acceptable

  • Routine sterilization of instruments and media is required

What Materials Can Be Sterilized?

  • Laboratory instruments

  • Glassware (flasks, cylinders)

  • Culture media

  • Wrapped instruments

  • Textiles and dressings

  • Biohazard waste

Safety Features

  • Mechanical lid locking system

  • Pressure safety valve

  • Controlled steam release

  • Overpressure protection system

Frequently Asked Questions 

Q1. What is LMPOA-A109 used for?

       It is used for sterilizing laboratory instruments, glassware, media, textiles, and biohazard waste using pressurized steam.

Q2. Can it sterilize liquid media?

      Yes, it supports sterilization of liquid culture media and reagents.

Q3. Is it suitable for field laboratories?

      Yes, its compact design supports mobile and decentralized lab setups.

Q4. What is the operating temperature?

       It operates between 105°C and 134°C depending on cycle settings.

Q4. How is sterilization achieved?

       Sterilization is achieved using saturated steam under controlled pressure and exposure time.

Typical Applications

  • Clinical instrument sterilization

  • Microbiology media preparation

  • Laboratory glassware sterilization

  • Biohazard waste decontamination

  • Veterinary laboratory sterilization

Compliance Standards

LMPOA-A109 follows:

  • ISO 17665 sterilization guidelines

  • Good Laboratory Practice (GLP)

  • Clinical laboratory safety standards

  • Internal QA documentation protocols

Quick Summary

LMPOA-A109 is a portable vertical steam autoclave used in laboratories and clinical environments for sterilizing instruments, glassware, media, textiles, and biohazard waste. It operates at 105–134°C under controlled pressure and is suitable for compact, mobile, and space-limited laboratory environments.