Get Quote
Contact us now to receive a detailed quotation.
LMPOA-A108 is a vertical portable steam sterilizer designed for laboratory sterilization of instruments and materials using pressurized saturated steam.
It is used where compact size, flexible placement, and manual sterilization control are required.
It sterilizes laboratory materials by exposing them to high-temperature saturated steam under controlled pressure for a defined time period.
Surgical and laboratory instruments
Glassware (flasks, beakers, cylinders)
Culture media and reagents
Wrapped instrument packs
Biohazard laboratory waste
Research consumables
It works by generating saturated steam inside a sealed vertical chamber and maintaining it at sterilization temperature and pressure for microbial inactivation.
Vertical loading of materials
Mechanical sealing of chamber
Electric steam generation
Sterilization at 105–134°C
Controlled exposure phase
Safe pressure release
LMPOA-A108 is used in:
Pharmaceutical laboratories
Biotechnology research centers
Clinical diagnostic labs
Veterinary hospitals
Academic institutions
Field and mobile laboratories
Use case intent:
It is suitable when sterilization is required in compact or decentralized laboratory environments.
Stainless steel vertical chamber
Adjustable temperature control
Pressure monitoring gauge
Timer-based cycle system
Safety valve for pressure release
Electric heating system
Compact portable design
Heat-insulated handles
Sterilization of solid and liquid lab materials
Moist heat microbial inactivation
Batch processing for small–medium loads
SOP-based sterilization support
Biohazard decontamination support
Temperature Range: 105°C – 134°C
Pressure Range: 0.1 – 0.22 MPa
Chamber Type: Vertical stainless steel
Control System: Manual timer-based
Power Supply: 220V AC, 50/60 Hz
Loading Type: Top-loading
LMPOA-A108 when compact vertical sterilization with portable installation and manual control is required.
Laboratory space is limited
Field or mobile sterilization is required
Small to medium batch processing is needed
Manual control is acceptable
Routine sterilization workflows are performed
Supports contamination-free laboratory workflow
Enables sterilization in mobile and field environments
Helps maintain biohazard safety compliance
Improves flexibility in decentralized lab setups
LMPOA-A108 is designed for compact sterilization workflows and differs from benchtop or horizontal autoclaves that are optimized for different capacity and workflow needs.
It is used for sterilizing laboratory instruments, glassware, media, textiles, and biohazard waste using steam.
Yes, it supports sterilization of liquid culture media using controlled exposure time.
Yes, its portable design supports mobile and field laboratory use.
It operates between 105°C and 134°C.
Yes, trained personnel are required for safe operation.
Yes, it is used for decontamination before disposal.
ISO 17665
GLP (Good Laboratory Practice)
Clinical laboratory sterilization guidelines
Laboratory sterilization workflows
Microbiology contamination control
Pharmaceutical QA sterilization
Veterinary sterilization procedures