Labmate Portable Autoclave LMPOA-A107


Portable Autoclave LMPOA-A107 – Vertical Steam Sterilization Unit

What is LMPOA-A107 Portable Autoclave?

LMPOA-A107 is a vertical top-loading portable steam autoclave used for sterilizing laboratory instruments, glassware, culture media, textiles, and biohazard materials. It operates using controlled steam at 105°C to 134°C with regulated pressure cycles for microbial inactivation in laboratory and clinical environments.

This system is used in laboratories where compact sterilization equipment is required for routine decontamination and sample processing workflows.

What is a Portable Autoclave Used For?

A portable autoclave is used for steam sterilization in environments where space is limited or mobility is required.

LMPOA-A107 is used for:

  • Sterilization of surgical and laboratory instruments

  • Glassware sterilization in microbiology labs

  • Culture media and reagent sterilization

  • Biohazard waste decontamination

  • Textile and dressing sterilization in clinical settings

How Does LMPOA-A107 Work? 

The sterilization process follows these steps:

  1. Materials are placed inside the vertical stainless steel chamber

  2. The lid is locked using mechanical clamps

  3. Water is heated to generate saturated steam

  4. Temperature rises to 105–134°C under pressure

  5. Sterilization is maintained for a defined cycle time

  6. Pressure is slowly released after cycle completion

  7. Materials are safely removed after cooling

Summary: The system uses controlled steam and pressure to eliminate microorganisms through thermal exposure.

Where is LMPOA-A107 Used?

LMPOA-A107 is used in laboratories that require compact sterilization systems:

  • Pharmaceutical quality control labs

  • Biotechnology and microbiology research labs

  • Clinical diagnostic laboratories

  • Veterinary clinics

  • Academic institutions

  • Field and mobile laboratories

Can LMPOA-A107 Sterilize Biohazard Waste?

Yes.  Autoclave is used to sterilize biohazard waste before disposal. It uses high-temperature steam to deactivate microorganisms and reduce contamination risk before final disposal according to laboratory safety protocols.

What Temperature Does LMPOA-A107 Operate At?

LMPOA-A107 operates within:

  • Temperature range: 105°C to 134°C

  • Pressure range: 0.1 to 0.22 MPa

These parameters are selected based on load type and sterilization requirements.

Key Features of LMPOA-A107

  • Vertical stainless steel chamber

  • Manual timer-based control system

  • Pressure gauge for real-time monitoring

  • Safety valve for pressure control

  • Electric heating system

  • Compact portable structure

  • Heat-insulated handling system

Technical Specifications

Parameter

Specification

Sterilization Temperature

105°C – 134°C

Working Pressure

0.1 – 0.22 MPa

Chamber Type

Vertical Stainless Steel

Control System

Manual Timer Control

Power Supply

220 V AC, 50/60 Hz

Application

Laboratory & Clinical Sterilization

How to Select LMPOA-A107

This model is suitable when:

  • Laboratory space is limited

  • Small to medium batch sterilization is required

  • Portable sterilization setup is needed

  • Manual cycle control is acceptable

  • Routine sterilization of instruments and media is required

What Materials Can Be Sterilized?

LMPOA-A107 supports:

  • Metal instruments

  • Glassware (flasks, beakers)

  • Liquid culture media

  • Wrapped instruments

  • Laboratory textiles

  • Non-hazardous consumables

Safety Features

  • Pressure safety valve

  • Mechanical lid locking system

  • Controlled steam release system

  • Thermal protection system

Frequently Asked Questions

Q1. What is LMPOA-A107 used for?

       It is used for sterilizing laboratory instruments, glassware, culture media, textiles, and biohazard waste using steam under pressure.

Q2. Can it sterilize liquid media?

       Yes, liquid media can be sterilized using controlled exposure cycles.

Q3. Is it suitable for microbiology labs?

      Yes, it is commonly used in microbiology and research laboratories.

Q4. What is the operating temperature?

       It operates between 105°C and 134°C depending on cycle selection.

Q5. Can it be used in field labs?

      Yes, its compact vertical design supports mobile laboratory environments.

Typical Applications

  • Clinical instrument sterilization

  • Microbiology media preparation

  • Laboratory glassware sterilization

  • Biohazard waste decontamination

  • Veterinary clinic sterilization workflows

Compliance Standards

LMPOA-A107 supports sterilization practices aligned with:

  • ISO 17665 sterilization guidelines

  • Good Laboratory Practice (GLP)

  • Clinical laboratory safety protocols

  • Internal QA documentation systems

Quick Summary

LMPOA-A107 is a vertical portable steam autoclave used in laboratories and clinical environments for sterilizing instruments, glassware, culture media, textiles, and biohazard waste. It operates at 105–134°C under controlled pressure and supports compact laboratory workflows requiring manual cycle control and space efficiency.