LMHA-B100 is a horizontal front-loading steam autoclave used for sterilizing laboratory instruments, glassware, culture media, and textiles using controlled temperature and pressure cycles. It supports laboratory, clinical, and pharmaceutical sterilization processes with programmable operation and digital monitoring aligned with ISO 17665 and GLP documentation.
Used for: Instruments, media, textiles, biohazard waste
Temperature range: 105°C to 134°C
Load types: Solid, liquid, wrapped, porous
Operation: Programmable steam sterilization cycles
Application: Laboratories, hospitals, pharmaceutical facilities
If your facility requires:
Sterilization of mixed loads (liquid + solid + wrapped)
Controlled and repeatable sterilization cycles
Documentation for audits and compliance
Structured batch processing
LMHA-B100 fits these requirements through programmable control, uniform steam exposure, and digital parameter tracking.
Load materials into the horizontal chamber
Secure the front door with interlocks
Remove air via gravity or vacuum
Introduce saturated steam at set temperature
Maintain exposure for defined time
Release pressure in a controlled manner
Complete drying before unloading
Laboratory instruments (metal tools)
Glassware (flasks, bottles)
Culture media and reagents
Wrapped surgical trays
Cleanroom garments
Biohazard waste
Pharmaceutical labs
Biotechnology research centers
Hospital sterile departments (CSPD)
Academic labs
Food testing labs
Diagnostic labs
Handles solid, liquid, and porous loads
Programmable sterilization cycles
Uniform steam distribution
Supports GLP documentation
Suitable for microbial inactivation
Horizontal autoclave: Suitable for large batch loads and structured loading
Vertical autoclave: Suitable for smaller labs with limited space
Front-loading systems improve workflow organization
Horizontal models support higher throughput
Choose LMHA-B100 if you need:
Medium batch sterilization capacity
Front-loading access for workflow control
Programmable cycles for SOP compliance
Mixed load sterilization capability
Laboratories may also consider:
Vertical autoclaves for space-efficient laboratory layouts
Benchtop autoclaves for low-volume sterilization applications
Pass-through autoclaves for cleanroom and controlled environments
Dry heat sterilizers for materials incompatible with steam sterilization
It is used to sterilize laboratory and clinical materials using steam under pressure, including instruments, liquids, and textiles.
Yes, programmable cycles allow safe sterilization of liquid media and reagents.
Typical cycles range from 20 to 60 minutes depending on load type.
Most cycles operate between 105°C and 134°C.
Yes, it supports laboratory sterilization workflows and documentation.
LMHA-B100 is used in environments where controlled steam sterilization is required for laboratory safety, contamination control, and validated workflows.
Common applications include:
Sterilization of surgical instruments in clinical labs
Preparation of culture media in research facilities
Glassware sterilization in academic laboratories
Decontamination of biohazard waste before disposal
Sterilization of cleanroom garments and textiles
ISO 17665
Good Laboratory Practice (GLP)
Clinical sterilization protocols
To help users understand sterilization systems in detail, related content should guide them toward selection, comparison, and technical understanding.
Recommended internal links:
Horizontal Autoclaves → overview of all horizontal models
Vertical Autoclaves → compact sterilization systems
Digital Steam Sterilizers → automation-focused systems
Sterilization Equipment Guide → selection and buying guide
Steam Sterilization Science → technical working principles