Labmate Horizontal Autoclave LMHA-A502


Horizontal Autoclave LMHA-A502 – Front-Loading Steam Sterilization System

What is LMHA-A502?

LMHA-A502 is a horizontal front-loading steam autoclave used for sterilizing laboratory and clinical materials using controlled temperature (105°C–134°C) and pressure cycles. It supports sterilization of instruments, glassware, liquids, textiles, and biohazard waste while aligning with ISO 17665 and GLP practices.

Quick Answer Summary

  • Type: Horizontal steam autoclave

  • Loading: Front-loading

  • Temperature Range: 105°C – 134°C

  • Applications: Instruments, liquids, textiles, glassware, waste

  • Industries: Pharmaceutical, healthcare, research laboratories

  • Compliance: ISO 17665, GLP

What is LMHA-A502 Used For?

LMHA-A502 is used to sterilize:

  • Stainless steel instruments

  • Laboratory glassware

  • Culture media and reagents

  • Wrapped surgical trays

  • Cleanroom garments

  • Biohazard waste

It supports contamination control and sterile processing workflows.

How Does LMHA-A502 Work?

  1. Materials are loaded into the chamber

  2. Door is sealed using safety interlocks

  3. Air is removed (gravity or vacuum method)

  4. Steam reaches programmed temperature

  5. Load is held for exposure time

  6. Pressure is released in a controlled manner

  7. Drying phase completes the cycle

Key Features at a Glance

  • Microprocessor-controlled sterilization cycles

  • Adjustable temperature and exposure time

  • Horizontal stainless steel chamber

  • Real-time monitoring of cycle parameters

  • Automatic steam and exhaust control

  • Door interlock safety mechanism

Can LMHA-A502 Sterilize Liquids and Biohazard Waste?

Yes. It supports:

  • Liquid sterilization using controlled heating cycles

  • Biohazard waste decontamination before disposal

  • Sterilization of wrapped and porous materials

Is LMHA-A502 Suitable for Hospitals and Laboratories?

Yes. It is used in:

  • Hospital sterile processing departments (CSPD)

  • Pharmaceutical laboratories

  • Biotechnology research centers

  • Academic and diagnostic laboratories

When Should You Choose LMHA-A502?

Choose this model if:

  • High-capacity sterilization is required

  • Mixed loads (liquids, solids, textiles) are processed

  • Documentation is required for audits

  • Biohazard waste sterilization is needed

  • Front-loading improves workflow organization

When This Autoclave May Not Be Suitable

  • Small-volume sterilization → use benchtop autoclave

  • Limited space → consider vertical autoclave

  • Heat-sensitive materials → use alternative sterilization methods

Horizontal vs Vertical Autoclave

  • Horizontal autoclave: Suitable for large batches and structured loading

  • Vertical autoclave: Suitable for smaller loads and compact spaces

Technical Specifications

  • Temperature Range: 105°C – 134°C

  • Pressure Range: 0.1 – 0.25 MPa

  • Chamber: Horizontal stainless steel

  • Control: Digital microprocessor

  • Power Supply: 220 V AC, 50/60 Hz

  • Loading Type: Front-loading

Frequently Asked Questions

Q1. What is LMHA-A502 used for?

       It is used for steam sterilization of instruments, glassware, liquids, textiles, and laboratory waste in clinical and research environments.

Q2. Can it sterilize liquid media?

       Yes, programmable cycles allow sterilization of liquid media and reagents.

Q3. What temperature does it operate at?

       It operates between 105°C and 134°C depending on the selected cycle.

Q4. Is it suitable for hospital use?

     Yes, it supports hospital sterile processing workflows including CSPD applications.

Q5. Can it sterilize biohazard waste?

      Yes, it is used for decontaminating laboratory biohazard waste before disposal.

Q6. How are sterilization parameters monitored?

       Temperature, pressure, and cycle duration are displayed in real time through a digital control interface.

Q7. Does it support compliance requirements?

       Yes, it aligns with ISO 17665 and GLP documentation practices.

Typical Applications

  • Sterilization of surgical instruments

  • Laboratory media preparation

  • Glassware sterilization

  • Biohazard waste decontamination

  • Textile sterilization

Compliance Alignment

  • ISO 17665 – Steam sterilization

  • Good Laboratory Practice (GLP)

  • Clinical laboratory sterilization protocols

Executive  Summary

LMHA-A502 is suitable for laboratories and hospitals requiring high-capacity steam sterilization, mixed load processing, and programmable cycle control for compliance and documentation.