LMHA-A502 is a horizontal front-loading steam autoclave used for sterilizing laboratory and clinical materials using controlled temperature (105°C–134°C) and pressure cycles. It supports sterilization of instruments, glassware, liquids, textiles, and biohazard waste while aligning with ISO 17665 and GLP practices.
Type: Horizontal steam autoclave
Loading: Front-loading
Temperature Range: 105°C – 134°C
Applications: Instruments, liquids, textiles, glassware, waste
Industries: Pharmaceutical, healthcare, research laboratories
Compliance: ISO 17665, GLP
LMHA-A502 is used to sterilize:
Stainless steel instruments
Laboratory glassware
Culture media and reagents
Wrapped surgical trays
Cleanroom garments
Biohazard waste
It supports contamination control and sterile processing workflows.
Materials are loaded into the chamber
Door is sealed using safety interlocks
Air is removed (gravity or vacuum method)
Steam reaches programmed temperature
Load is held for exposure time
Pressure is released in a controlled manner
Drying phase completes the cycle
Microprocessor-controlled sterilization cycles
Adjustable temperature and exposure time
Horizontal stainless steel chamber
Real-time monitoring of cycle parameters
Automatic steam and exhaust control
Door interlock safety mechanism
Yes. It supports:
Liquid sterilization using controlled heating cycles
Biohazard waste decontamination before disposal
Sterilization of wrapped and porous materials
Yes. It is used in:
Hospital sterile processing departments (CSPD)
Pharmaceutical laboratories
Biotechnology research centers
Academic and diagnostic laboratories
Choose this model if:
High-capacity sterilization is required
Mixed loads (liquids, solids, textiles) are processed
Documentation is required for audits
Biohazard waste sterilization is needed
Front-loading improves workflow organization
Small-volume sterilization → use benchtop autoclave
Limited space → consider vertical autoclave
Heat-sensitive materials → use alternative sterilization methods
Horizontal autoclave: Suitable for large batches and structured loading
Vertical autoclave: Suitable for smaller loads and compact spaces
Temperature Range: 105°C – 134°C
Pressure Range: 0.1 – 0.25 MPa
Chamber: Horizontal stainless steel
Control: Digital microprocessor
Power Supply: 220 V AC, 50/60 Hz
Loading Type: Front-loading
It is used for steam sterilization of instruments, glassware, liquids, textiles, and laboratory waste in clinical and research environments.
Yes, programmable cycles allow sterilization of liquid media and reagents.
It operates between 105°C and 134°C depending on the selected cycle.
Yes, it supports hospital sterile processing workflows including CSPD applications.
Yes, it is used for decontaminating laboratory biohazard waste before disposal.
Temperature, pressure, and cycle duration are displayed in real time through a digital control interface.
Yes, it aligns with ISO 17665 and GLP documentation practices.
Sterilization of surgical instruments
Laboratory media preparation
Glassware sterilization
Biohazard waste decontamination
Textile sterilization
ISO 17665 – Steam sterilization
Good Laboratory Practice (GLP)
Clinical laboratory sterilization protocols