LMHA-A403 is a horizontal front-loading autoclave used for Steam Sterilization of laboratory and clinical materials. It operates using controlled temperature (105°C–134°C) and pressure cycles to sterilize instruments, glassware, liquids, textiles, and wrapped items while supporting ISO 17665 and Good Laboratory Practice practices.
Used for: Sterilizing lab and clinical materials
Sterilization method: Saturated steam under pressure
Load types: Solid, liquid, wrapped, porous
Best for: High-capacity laboratory and hospital workflows
Temperature range: 105°C to 134°C
It is used to sterilize laboratory and clinical materials using high-temperature steam under pressure.
Stainless steel instruments
Borosilicate glassware
Culture media and reagents
Wrapped surgical trays
Cleanroom garments
Biohazard waste
LMHA-A403 is used in:
Pharmaceutical laboratories
Biotechnology research centers
Hospital CSSD/CSPD units
Academic institutions
Food testing laboratories
Materials are loaded into the horizontal chamber
Door is secured with interlocks
Air is removed (gravity or vacuum)
Steam enters and reaches set temperature
Exposure phase sterilizes materials
Controlled depressurization occurs
Drying phase completes the cycle
Microprocessor-controlled cycles
Adjustable temperature and time
Real-time pressure monitoring
Front-loading chamber design
Safety door interlock system
Automatic steam regulation
✔ Solid instruments
✔ Liquid media
✔ Wrapped materials
✔ Porous loads
✔ Laboratory waste
Choose this model if:
You require high batch capacity
Your workflow involves multiple load types
You need documentation for compliance audits
Your lab uses sterilization SOPs aligned with Good Laboratory Practice
Small laboratories with low throughput
Space-restricted environments
Applications requiring dry heat sterilization
Horizontal autoclaves → Large batch processing
Vertical autoclaves → Space-efficient setups
Benchtop autoclaves → Small-scale sterilization
Yes, programmable cycles allow safe sterilization of liquids without overflow.
Most cycles range from 20 to 60 minutes depending on load type.
Yes, it supports sterile processing workflows in clinical environments.
Yes, it aligns with ISO 17665 and Good Laboratory Practice requirements.
Door interlocks
Pressure monitoring
Emergency shutdown system
Sterilizing surgical instruments
Preparing microbiological media
Decontaminating laboratory waste
Processing cleanroom textiles
This autoclave aligns with:
ISO 17665
Good Laboratory Practice
Clinical sterilization protocols