Get Quote
Contact us now to receive a detailed quotation.
LMHA-A401 is a horizontal front-loading steam autoclave used for sterilizing laboratory and clinical materials using controlled temperature (105°C–134°C) and pressure cycles. It supports sterilization of instruments, glassware, liquids, textiles, and biohazard waste while aligning with ISO 17665 and GLP practices.
Type: Horizontal steam autoclave
Loading: Front-loading
Temperature Range: 105°C – 134°C
Applications: Instruments, liquids, textiles, glassware
Industries: Pharma, healthcare, laboratories
Compliance: ISO 17665, GLP
LMHA-A401 is used to sterilize:
Surgical and laboratory instruments
Borosilicate glassware
Culture media and reagents
Wrapped instrument trays
Cleanroom garments
Laboratory biohazard waste
It supports contamination control and sterile processing workflows in regulated environments.
Materials are loaded into horizontal chamber
Door is sealed using safety interlocks
Air is removed via gravity or vacuum
Steam enters and reaches set temperature
Load is held for defined exposure time
Controlled depressurization occurs
Drying phase completes the cycle
Microprocessor-controlled sterilization cycles
Adjustable temperature and exposure time
Horizontal stainless steel chamber
Real-time monitoring of pressure and temperature
Automatic steam and exhaust control
Integrated safety interlocks
Yes. Labmate system supports sterilization of:
Liquid media using controlled heating cycles
Wrapped and porous materials through steam penetration
Yes. It is used in:
Hospital sterile processing departments (CSPD)
Pharmaceutical laboratories
Research institutions
Diagnostic laboratories
Choose this model if:
You need high-capacity sterilization
You process mixed loads (liquids + solids)
You require documented sterilization cycles
You handle wrapped or porous materials
You need front-loading workflow efficiency
Low-volume sterilization needs → use benchtop autoclave
Space constraints → consider vertical autoclave
Heat-sensitive materials → use alternative sterilization methods
Horizontal autoclave: Suitable for large batch sterilization and organized loading
Vertical autoclave: Suitable for compact spaces and smaller loads
Temperature Range: 105°C – 134°C
Pressure Range: 0.1 – 0.25 MPa
Chamber: Horizontal stainless steel
Control System: Digital microprocessor
Power Supply: 220 V AC, 50/60 Hz
It is used for steam sterilization of laboratory instruments, glassware, liquids, textiles, and biohazard waste.
Yes, it supports liquid sterilization using programmable cycles.
It operates between 105°C and 134°C depending on the cycle.
Yes, it supports hospital sterile processing workflows.
Temperature, pressure, and time are displayed digitally in real time.
Yes, it aligns with ISO 17665 and GLP documentation practices.
Sterilization of surgical instruments
Laboratory media preparation
Glassware sterilization
Biohazard waste decontamination
Textile sterilization
ISO 17665 – Steam sterilization standards
Good Laboratory Practice (GLP)
Clinical sterilization protocols