Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Labmate Horizontal Autoclave LMHA-A302


Horizontal Autoclave LMHA-A302 – Front-Loading Steam Sterilizer

What is LMHA-A302 Horizontal Autoclave?

LMHA-A302 is a horizontal front-loading steam sterilizer used in laboratories, hospitals, and pharmaceutical environments. It sterilizes instruments, glassware, media, textiles, and wrapped materials using controlled steam under high temperature and pressure conditions. It is used where validated sterilization cycles and batch processing are required.

What is a Horizontal Autoclave used for?

A horizontal autoclave is used for sterilizing laboratory and clinical materials using saturated steam under controlled conditions. It is commonly used for:

  • Surgical instruments

  • Glassware and laboratory flasks

  • Culture media and reagents

  • Wrapped sterile packs

  • Textiles and protective garments

  • Biohazard laboratory waste

It is used when repeatable sterilization cycles are required in controlled environments.

How does LMHA-A302 work? 

Step 1: Loading
Materials are placed inside the horizontal stainless steel chamber.

Step 2: Door sealing
The chamber door is locked using mechanical and electronic interlocks.

Step 3: Air removal
Air is removed using gravity displacement or vacuum-assisted pre-conditioning.

Step 4: Steam injection
Saturated steam is introduced into the chamber.

Step 5: Sterilization phase
Materials are exposed to controlled temperature and pressure for a set duration.

Step 6: Cooling & drying
Pressure is released and drying prepares items for safe removal.

Where is LMHA-A302 used?

LMHA-A302 is used in:

  • Pharmaceutical manufacturing labs

  • Biotechnology research centers

  • Hospital sterilization departments (CSPD)

  • Clinical diagnostic laboratories

  • Academic research institutions

  • Food testing laboratories

It is used where high-capacity sterilization of mixed laboratory loads is required.

Why is LMHA-A302 used?

LMHA-A302 is used because it enables controlled steam sterilization that reduces microbial contamination in laboratory materials. It supports repeated sterilization cycles required in pharmaceutical and clinical workflows.

It is also used where documentation of sterilization cycles is required for compliance systems.

What materials can be sterilized?

LMHA-A302 can sterilize:

  • Metal instruments

  • Glass containers

  • Liquid media

  • Wrapped surgical packs

  • Textiles and garments

  • Laboratory waste materials

Heat-sensitive and flammable materials are not suitable.

Technical Specifications 

  • Temperature Range: 105°C – 134°C (sterilization operating range)

  • Pressure Range: 0.1 – 0.25 MPa (steam saturation control)

  • Chamber Type: Horizontal stainless steel chamber

  • Control System: Digital microprocessor-based system

  • Power Supply: 220V AC, 50/60 Hz

  • Loading Type: Front-loading batch sterilization

Operational Features

  • Programmable sterilization cycles

  • Real-time temperature and pressure monitoring

  • Door interlock safety system

  • Controlled steam flow and exhaust system

  • Digital cycle display

  • Stainless steel chamber structure

How to choose LMHA-A302?

This model is suitable when:

  • Large sterilization batches are required

  • Mixed loads are processed regularly

  • Structured horizontal loading is preferred

  • Audit documentation is required

  • High cycle repeatability is needed

LMHA-A302 vs other autoclaves

Compared to vertical autoclaves, LMHA-A302 supports higher batch organization and better load separation. Compared to benchtop systems, it is used for larger sterilization requirements. Compared to pass-through systems, it is used in non-cleanroom batch workflows.

Frequently Asked Question

Q1. What is LMHA-A302 used for?
       It is used for steam sterilization of laboratory instruments, glassware, media, textiles, and clinical materials.

Q2. What is its temperature range?
       It operates between 105°C and 134°C depending on cycle settings.

Q3. Can liquids be sterilized?
      Yes, liquid media and reagents can be sterilized using controlled cycles.

Q4. Is it used in hospitals?
       Yes, it is used in hospital sterilization departments and CSPD units.

Q5. Does it support cycle logging?
       Yes, it supports digital monitoring and cycle recording.

Typical Applications

  • Surgical instrument sterilization

  • Media preparation in laboratories

  • Glassware sterilization

  • Waste decontamination

  • Textile sterilization in clean environments

Compliance Standards

LMHA-A302 supports sterilization workflows aligned with:

  • ISO 17665 sterilization standard

  • Good Laboratory Practice (GLP)

  • Hospital sterilization protocols

  • Laboratory documentation systems

Quick Summary

LMHA-A302 is a horizontal front-loading autoclave used for sterilizing laboratory and clinical materials using controlled steam cycles (105°C–134°C). It is used in hospitals, pharmaceutical labs, and research facilities for sterilizing instruments, glassware, media, textiles, and wrapped loads with programmable cycle control and monitoring.