Get Quote
Contact us now to receive a detailed quotation.
LMHA-A201 is a horizontal front-loading steam autoclave used for sterilizing laboratory instruments, glassware, media, textiles, and consumables. It operates using saturated steam at 105–134°C under controlled pressure conditions to eliminate microorganisms and spores in laboratory and clinical environments.
It is designed for medium to high-capacity sterilization workflows in pharmaceutical, hospital, and research facilities.
What does it do? Steam sterilization of lab materials
Temperature range? 105°C – 134°C
Pressure range? 0.1 – 0.25 MPa
Load types? Instruments, glassware, media, textiles, waste
Cycle type? Programmable digital sterilization cycles
LMHA-A201 is used for sterilizing laboratory and clinical materials such as:
Surgical and lab instruments
Glassware and flasks
Culture media and reagents
Wrapped surgical trays
Cleanroom textiles
Biohazard waste
It supports contamination control and sterile workflow requirements in regulated environments.
Door locks with safety interlock system
Air is removed using gravity or vacuum system
Steam enters and reaches sterilization temperature
Cycle completes with pressure release and drying
Programmable sterilization cycles
Horizontal stainless steel chamber
Front-loading structure
Real-time digital monitoring
Pressure and temperature control
Safety interlock system
Automatic steam exhaust regulation
Temperature: 105°C – 134°C
Pressure: 0.1 – 0.25 MPa
Chamber: Horizontal stainless steel
Control: Digital microprocessor
Cycle: Programmable timing
Power: 220V AC
Sterilization of solid, porous, and liquid loads
Uniform steam penetration
Adjustable cycle programming
Compliance with GLP and ISO sterilization protocols
Microbial and spore inactivation using high-pressure steam
This system is suitable for:
Pharmaceutical manufacturing labs
Biotechnology research centers
Hospital sterilization departments
University laboratories
Clinical diagnostic labs
Food testing laboratories
Choose this model when:
High batch sterilization is required
Front-loading workflow is preferred
Digital cycle documentation is needed
Regulatory compliance is mandatory
Mixed laboratory loads are processed
ISO 17665 Sterilization Standard
Good Laboratory Practice (GLP)
Hospital sterilization protocols
Laboratory quality documentation systems
Surgical instrument sterilization
Media preparation in labs
Glassware sterilization
Biohazard waste decontamination
Cleanroom textile sterilization
It is used for sterilizing laboratory instruments, glassware, media, textiles, and waste using high-pressure steam.
It operates between 105°C and 134°C depending on the selected cycle.
Yes, it supports safe sterilization of liquid media and reagents.
Yes, it is used in hospital sterile processing departments.
It has a horizontal stainless steel front-loading chamber.
Yes, sterilization cycles can be fully programmed.
It follows ISO 17665 and GLP compliance guidelines.
Yes, small laboratory waste loads can be sterilized before disposal.