Get Quote
Contact us now to receive a detailed quotation.
Labmate LMAQM-A133 is a multi-parameter indoor air quality monitor used to measure CO₂, particulate matter (PM1.0, PM2.5, PM10), formaldehyde (HCHO), TVOC, temperature, humidity, and AQI in real time for indoor environmental assessment in laboratories, healthcare spaces, offices, and classrooms.
Labmate LMAQM-A133 measures:
CO₂ (ventilation and air freshness indicator)
PM1.0 / PM2.5 / PM10 (fine and coarse airborne particles)
HCHO (formaldehyde gas from materials and chemicals)
TVOC (total volatile organic compounds from indoor sources)
Temperature (thermal comfort level)
Humidity (moisture balance in air)
AQI (combined air quality index)
Indoor air monitoring is important because it helps identify:
Poor ventilation (high CO₂ levels)
Respiratory risks (PM2.5 exposure)
Chemical exposure (VOC and HCHO presence)
Comfort imbalance (humidity and temperature changes)
AQI (Air Quality Index) is a calculated value that represents overall indoor air condition based on:
particulate concentration
gas levels
environmental conditions
Higher AQI indicates poorer air quality conditions.
Labmate LMAQM-A133 works by continuously sampling indoor air through multiple sensors:
CO₂ is measured using NDIR infrared sensing
PM1.0/PM2.5/PM10 is measured using laser scattering technology
HCHO and TVOC are measured using electrochemical sensors
temperature and humidity are measured using integrated digital sensors
All readings are processed in real time to generate AQI values displayed on a digital screen.
NDIR sensor is used for CO₂ because it detects gas absorption accurately
Laser scattering is used for PM because it detects particle density in air
Electrochemical sensors are used for VOC/HCHO because they react to chemical compounds in air
Real-time multi-parameter air monitoring
AQI calculation and display
Continuous indoor sampling
Portable battery-powered operation
Automatic calibration system
Compact deployment design
It is used in:
Laboratories for controlled air monitoring
Healthcare environments for safety compliance
Offices for ventilation and air quality tracking
Classrooms for student exposure control
Research centers for environmental studies
LMAQM-A129 → Basic portable monitoring
LMAQM-A130 → Healthcare and advanced monitoring
LMAQM-A131 → Laboratory-focused monitoring
LMAQM-A132 → Structured indoor IAQ monitoring
LMAQM-A133 → Multi-environment research and compliance monitoring
CO₂ Range: 400–5000 ppm
PM Range: 0–999 µg/m³
HCHO Range: 0.001–1.999 mg/m³
TVOC Range: 0.001–9.999 mg/m³
AQI Range: 0–500
Sensor Types: NDIR, Laser Scattering, Electrochemical
Power: Rechargeable lithium battery
Display: Digital LCD
Choose this model when:
Multi-parameter air tracking is required
AQI reporting is needed for documentation
Portable indoor monitoring is required
Laboratory or healthcare air compliance is required
Research-grade environmental tracking is needed
Q1. What is CO₂ monitoring used for?
CO₂ monitoring is used to evaluate ventilation efficiency and indoor air freshness.
Q2. What does PM2.5 mean?
PM2.5 refers to fine airborne particles that can enter lungs and affect respiratory health.
Q3. What is TVOC in indoor air?
TVOC represents total volatile organic compounds released from chemicals, paints, and indoor materials.
Q4. Why is AQI important?
AQI provides a single value representing overall indoor air quality status.
Q5. Is Labmate LMAQM-A133 suitable for laboratories?
Yes, it is designed for laboratory-grade indoor air monitoring.
Q6. Does it support continuous monitoring?
Yes, it supports continuous real-time indoor air tracking.
Laboratories → controlled air validation
Healthcare → infection and exposure control
Offices → ventilation optimization
Classrooms → exposure reduction for occupants
Research centers → environmental data collection
Labmate LMAQM-A133 supports indoor air monitoring aligned with:
Indoor environmental safety frameworks
Laboratory air quality documentation standards
Occupational exposure monitoring guidelines