Get Quote
Contact us now to receive a detailed quotation.
Indoor Air Quality Monitor LMAQM-A120 is a device that measures PM1.0, PM2.5, PM10, ozone (O₃), TVOC, temperature, humidity, and AQI in real time for indoor air quality assessment in laboratories, offices, homes, and public buildings.
It continuously monitors particulate matter, ozone, and VOC levels, then displays real-time air quality data to help users evaluate indoor air conditions and identify pollution changes.
Laboratories and research environments
Office buildings and workspaces
Residential indoor air checks
Public indoor environments
Environmental monitoring programs
Step 1: Air enters the sensing chamber through intake vents
Step 2: Laser scattering detects particulate matter (PM1.0–PM10)
Step 3: Electrochemical sensor measures ozone (O₃) levels
Step 4: Semiconductor sensor detects TVOC concentration
Step 5: Temperature and humidity are recorded simultaneously
Step 6: System calculates AQI and displays results in real time
Multi-parameter air quality measurement
Real-time AQI calculation
Detection of ozone and VOC gases
Portable design for flexible monitoring
Battery-powered operation
Instant digital display of results
It detects particulate matter (PM1.0, PM2.5, PM10), ozone (O₃), TVOC gases, temperature, humidity, and calculates AQI for indoor air evaluation.
Step 1: Power on the device
Step 2: Place it in a stable indoor airflow area
Step 3: Keep at breathing height (1–1.5 meters)
Step 4: Allow readings to stabilize for accurate results
Step 5: Observe real-time AQI and pollutant levels
When ozone monitoring is required
When VOC + particulate monitoring is needed together
When portable indoor air testing is preferred
When real-time AQI tracking is required
When multi-pollutant detection is required in one device
A120: Includes ozone (O₃) + PM + VOC monitoring
A110: Focused on CO₂ and formaldehyde
A120 advantage: broader gas detection coverage for environmental assessment
Does not measure CO₂ concentration
Not designed for outdoor meteorological analysis
Requires proper placement for stable accuracy
Clean air inlet periodically to avoid dust blockage
Calibration recommended based on usage intensity
Avoid placing near vents or direct emission sources
Stable indoor airflow improves measurement accuracy
Q1. What pollutants does Labmate LMAQM-A120 measure?
It measures PM1.0, PM2.5, PM10, ozone (O₃), TVOC, temperature, humidity, and AQI.
Q2. Can it detect ozone levels accurately?
Yes, it uses an electrochemical sensor for ozone measurement.
Q3. Is it suitable for office environments?
Yes, it is suitable for offices, labs, homes, and public indoor areas.
Q4. Does it measure VOC and particulate matter together?
Yes, both are measured simultaneously in real time.
Q5. Where should it be placed?
At breathing height, away from vents and direct airflow disturbances.
Q6. Can it run continuously?
Yes, it supports continuous indoor monitoring using battery power.
Indoor air monitoring in offices
Laboratory air quality tracking
Residential indoor pollution checks
Public building environmental assessment
Workplace safety monitoring
Supports indoor air quality monitoring aligned with:
Environmental indoor air guidelines
AQI-based reporting systems
Workplace air safety monitoring programs