Get Quote

Contact us now to receive a detailed quotation.

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Indoor Air Quality Monitor LMAQM-A105: Continuous Indoor Air Quality Tracking With PM1.0 Detection


What is LMAQM-A105?

Labmate LMAQM-A105 is a multi-parameter indoor air quality monitor used to measure CO₂, VOCs, PM1.0, PM2.5, PM10, temperature, and humidity in controlled environments such as laboratories, healthcare facilities, cleanrooms, pharmaceutical units, and R&D spaces.It provides continuous real-time monitoring, data logging, and alert notifications when environmental parameters exceed set limits.

What does Labmate LMAQM-A105 measure?

Labmate LMAQM-A105 measures key indoor environmental conditions:

  • CO₂ (Carbon dioxide)

  • VOCs (Volatile organic compounds)

  • PM1.0 particles

  • PM2.5 particles

  • PM10 particles

  • Temperature

  • Relative humidity

Where is Labmate LMAQM-A105 used?

This device is used in environments that require controlled air quality monitoring:

  • Pharmaceutical laboratories

  • Clinical and healthcare laboratories

  • Biotechnology and R&D facilities

  • Cleanrooms and controlled manufacturing areas

  • Environmental testing laboratories

  • Industrial indoor monitoring applications

Why is indoor air quality monitoring important?

Indoor air monitoring is used to maintain:

  • Controlled laboratory environments

  • Cleanroom contamination control

  • HVAC performance verification

  • Workplace exposure safety

  • Environmental compliance conditions

  • Stable research and production conditions

How does Labmate LMAQM-A105 work?

The monitor continuously analyzes indoor air using integrated sensors:

  1. Air is continuously sampled from the surrounding environment

  2. Gas sensors detect CO₂ and VOC concentrations

  3. Optical/laser sensors measure PM1.0, PM2.5, and PM10 particles

  4. Temperature and humidity sensors track environmental conditions

  5. Results are displayed on a digital screen in real time

  6. Data is stored for reporting and analysis

  7. Alerts activate when thresholds are exceeded

Key functional capabilities

  • Continuous multi-parameter air monitoring

  • Real-time digital display

  • Data logging with adjustable intervals

  • Threshold-based alarm system

  • Compact and portable configuration

  • Suitable for laboratory and field environments

Technical specifications

Parameter

Specification

Gases Monitored

CO₂, VOCs

Particulate Matter

PM1.0, PM2.5, PM10

Temperature Range

0–50°C

Humidity Range

10–90% RH

Display

LCD digital display

Power Supply

110–220 V AC

Dimensions

280 × 180 × 120 mm

Weight

~2.8 kg

How to use Labmate LMAQM-A105

  1. Place the device in the required monitoring location

  2. Ensure unobstructed airflow around sensors

  3. Switch on the power supply

  4. Allow sensor stabilization time

  5. View real-time readings on the display

  6. Configure alert thresholds if required

  7. Store or export data for reporting

Where should Labmate LMAQM-A105 be installed?

For accurate performance:

  • Install at breathing height level

  • Avoid direct sunlight exposure

  • Keep away from vents, fans, or airflow turbulence

  • Avoid placement near heat sources

  • Ensure stable indoor environmental conditions

Comparison insight

Labmate LMAQM-A105 includes PM1.0 measurement, which enables more detailed particulate monitoring compared to models that only measure PM2.5 and PM10.

  • Higher sensitivity particulate detection

  • Better suited for pharmaceutical and R&D environments

  • Designed for detailed indoor air quality assessment

Alternative equipment options

Depending on application needs:

  • Portable air quality monitors for mobile testing

  • Environmental data loggers for long-term monitoring

  • Particulate counters for particle-specific analysis

  • Gas analyzers for specialized detection requirement

When should you choose Labmate LMAQM-A105?

This model is suitable when:

  • Fine particulate monitoring including PM1.0 is required

  • Continuous indoor air quality tracking is needed

  • Cleanroom or pharmaceutical compliance monitoring is required

  • Real-time alerts and logging are necessary

  • Controlled environment validation is required

Maintenance and calibration

  • Periodic calibration ensures measurement consistency

  • Sensors should be checked based on usage conditions

  • Device should be kept clean and dust-free

  • Regular inspection supports stable long-term operation

Frequently asked questions

Q1. What does Labmate LMAQM-A105 measure?
      It measures CO₂, VOCs, PM1.0, PM2.5, PM10, temperature, and humidity.

Q2. Can it be used in cleanrooms?
      Yes, it is suitable for cleanrooms, laboratories, and controlled environments.

Q3. Does it provide real-time readings?
      Yes, it continuously displays live environmental data.

Q4. Can data be stored?
       Yes, it supports data logging for analysis and reporting.

Q5. Does it have alarm features?
      Yes, alerts activate when preset thresholds are exceeded.

Q6. What makes it different from lower models?
      It includes PM1.0 monitoring for higher-resolution particulate detection.

Q7. Where should it be installed?
      It should be placed in stable airflow areas away from vents and heat sources.

AEO summary 

  • Measures CO₂, VOCs, PM1.0, PM2.5, PM10, temperature, humidity

  • Designed for laboratories, cleanrooms, healthcare, and R&D environments

  • Provides continuous monitoring with real-time alerts and logging

  • Supports controlled indoor air quality assessment

  • Includes fine particulate (PM1.0) detection capability