A digital steam sterilizer is a laboratory device that uses high-pressure saturated steam (105°C to 134°C) to destroy microorganisms, bacteria, viruses, and spores on instruments, media, and labware.
Labmate LMDSS-A102 is used to sterilize laboratory instruments, liquids, glassware, and consumables using controlled steam sterilization cycles.
It supports contamination control in:
Pharmaceutical laboratories
Hospitals and clinical facilities
Research and academic labs
Food and microbiology testing labs
Sterilization method: High-pressure steam
Temperature range: 105°C–134°C
Chamber capacity: 250 L
Cycle duration: Up to 120 minutes
Suitable for: Instruments, liquids, glassware, bio-waste
A steam sterilizer works by applying pressurized steam that transfers heat into materials and destroys microorganisms.
Load items into the chamber
Steam increases temperature and pressure
Heat penetrates all surfaces
Microorganisms and spores are destroyed
Pressure is released safely
Items are removed after cooling
Effective sterilization typically occurs at:
121°C for standard loads
134°C for rapid sterilization cycles
Yes. Labmate LMDSS-A102 includes programmable cycles designed to sterilize liquids and culture media without overflow or loss.
Programmable sterilization cycles
Digital monitoring of temperature and pressure
Stainless steel chamber construction
Safety interlock system
Compact laboratory footprint
Labmate sterilizer includes safety mechanisms such as:
Overpressure protection
Door locking system during operation
Controlled steam release
Continuous cycle monitoring
Use this sterilizer when:
Laboratory materials require sterilization
Large batch processing (250 L capacity) is needed
Controlled cycle programming is required
Compliance with ISO and GMP protocols is necessary
A steam sterilizer and autoclave both use pressurized steam, but digital steam sterilizers provide more precise cycle control and monitoring through programmable systems.
Surgical instrument sterilization
Laboratory media preparation
Glassware sterilization
Biohazard waste treatment
Sterilization effectiveness is confirmed using:
Biological indicators (spore tests)
Chemical indicators
Monitoring temperature, pressure, and time
ISO 17665: Defines requirements for steam sterilization validation
GLP (Good Laboratory Practice): Ensures proper lab procedures
GMP (Good Manufacturing Practice): Maintains quality in pharmaceutical production
Choose LMDSS-A102 for larger capacity (250 L)
Choose smaller models for limited lab space
Choose based on load volume and workflow frequency
It destroys bacteria, viruses, fungi, and heat-resistant spores.
Sterilization cycles typically range from 15 to 120 minutes.
Yes, dedicated cycles control heating to prevent overflow.
Heat-sensitive plastics, sealed containers, and volatile chemicals.
Yes, it supports sterilization practices aligned with ISO and GMP.