Get Quote
Contact us now to receive a detailed quotation.
A high-pressure steam autoclave is a laboratory device that sterilizes instruments, media, and lab materials using pressurized steam at temperatures between 105°C and 134°C.
Labmate LMHS-A303 is used to sterilize large volumes of laboratory instruments, glassware, liquids, and consumables using programmable steam cycles.
It is used in:
Pharmaceutical manufacturing labs
Hospital sterilization units
Research and biotechnology laboratories
Food and quality testing facilities
Sterilization method: High-pressure steam
Temperature range: 105°C–134°C
Chamber volume: 600 L
Cycle time: 20–60 minutes typical
Applications: Instruments, liquids, media, labware
Steam sterilization removes harmful microorganisms by applying heat under pressure, making laboratory materials safe for further use.
Labmate LMHS-A303 uses controlled steam pressure to sterilize materials in a sealed chamber.
Load materials into chamber
Steam increases temperature and pressure
Heat penetrates all surfaces
Microorganisms and spores are destroyed
Pressure is safely released
Sterilized items are removed after cooling
121°C is used for standard sterilization
134°C is used for rapid or high-load sterilization
Yes. Programmable cycles control heating rates to safely sterilize liquids and culture media without overflow.
Programmable sterilization cycles
Large 600 L chamber capacity
Digital temperature and pressure monitoring
Safety interlock system
Real-time cycle tracking
The system includes:
Overpressure protection
Door locking during operation
Emergency shutdown system
Controlled pressure release
Use this sterilizer when:
Large-scale sterilization is required (600 L capacity)
High throughput laboratory workflows are present
Controlled sterilization cycles are needed
Compliance with ISO and GMP systems is required
An autoclave is a type of steam sterilizer that uses pressurized steam to eliminate microorganisms, while digital steam sterilizers provide programmable control and monitoring.
Sterilizing surgical instruments
Preparing laboratory culture media
Glassware sterilization
Biohazard waste treatment
Sterilization is confirmed using:
Biological indicators (spore tests)
Chemical indicators
Monitoring temperature, pressure, and time cycles
ISO 17665: Defines steam sterilization validation requirements
GLP: Ensures proper laboratory working procedures
GMP: Maintains pharmaceutical manufacturing quality systems
Choose Labmate LMHS-A303 for maximum capacity (600 L)
Choose smaller models for lower batch volumes
Selection depends on workflow scale and sterilization frequency
It sterilizes instruments, liquids, glassware, and lab consumables.
Typical cycles range from 20 to 60 minutes depending on load type.
Yes, controlled steam cycles prevent boiling over.
Heat-sensitive plastics, sealed containers, and volatile chemicals.
Yes, it supports ISO and GMP-based sterilization workflows.