Labmate LMDA-C102 is a high-capacity laboratory steam sterilizer that uses controlled high-pressure steam and programmable digital cycles to sterilize instruments, glassware, media, and consumables.
It is designed for large-scale sterilization in laboratories, hospitals, and pharmaceutical facilities.
Labmate LMDA-C102 eliminates microorganisms, spores, and contaminants using saturated steam under pressure, ensuring sterilization of laboratory materials.
Labmate LMDA-C102 is used for sterilizing laboratory instruments, culture media, glassware, and consumables using controlled steam cycles.
Large laboratory sterilization loads
Media and reagent preparation
Hospital instrument sterilization
Pharmaceutical cleanroom workflows
Bio-contamination control
Labmate LMDA-C102 operates through a controlled steam sterilization cycle:
Load materials into chamber
Seal chamber
Select sterilization program
Apply high-pressure steam
Maintain sterilization temperature
Cool and depressurize safely
Steam transfers heat efficiently and penetrates materials, making it effective for destroying microbial life at controlled temperatures.
Pharmaceutical manufacturing units
Biotechnology laboratories
Hospitals and surgical centers
Research institutions
Food testing laboratories
Labmate LMDA-C102 is suitable for facilities requiring large-volume sterilization with controlled digital cycles and compliance-driven workflows.
Large 150 L sterilization chamber
Digital cycle control system
High-pressure steam sterilization
Safety interlocks and monitoring
Stainless steel chamber construction
Real-time cycle tracking
Temperature: 105–134°C
Pressure: 0.1–0.25 MPa
Cycle Time: 0–120 minutes
Control: Digital interface
Heat-sensitive plastics
Flammable liquids
Sealed containers
Electronic devices
Sterilization is confirmed using biological indicators, chemical indicators, and monitoring of temperature, pressure, and time.
Overpressure protection
Door interlock system
Temperature sensors
Automatic shutdown system
Seal inspection
Pressure system checks
Water level monitoring
Calibration verification
Labmate LMDA-C101 for slightly smaller loads
Labmate LMDA-B series for medium capacity labs
Vertical autoclaves for compact installations
Labmate LMDA-C102 is positioned for extra-large sterilization workloads compared to lower capacity Labmate LMDA models, making it suitable for high-throughput laboratory environments.
Q1. What is Labmate LMDA-C102 used for?
It sterilizes laboratory instruments and materials using high-pressure steam.
Q2. How does it work?
It uses programmable steam cycles controlled digitally.
Q3. Can it sterilize liquids?
Yes, if compatible with cycle settings.
Q4. Is it suitable for hospitals?
Yes, it is used in hospital sterilization workflows.
Q5. What is the chamber size?
It has a 150 L sterilization chamber.
Hospital sterilization units
Pharmaceutical production labs
Research laboratories
Biotechnology facilities
Food testing labs
Labmate LMDA-C102 supports sterilization workflows aligned with:
ISO 17665
GLP guidelines
Hospital sterilization protocols