Digital Autoclave LMDA-B104 is a 60 L laboratory steam sterilizer that uses controlled high-pressure steam and programmable digital cycles to sterilize instruments, glassware, media, and consumables.It is used in laboratories, hospitals, and pharmaceutical environments requiring medium to large load sterilization.
Labmate LMDA-B104 sterilizes laboratory materials by exposing them to high-temperature saturated steam under pressure, eliminating microorganisms, spores, and biological contaminants.
Labmate LMDA-B104 is used for sterilizing laboratory instruments, glassware, culture media, and consumables using pressurized steam.
Laboratory instrument sterilization
Media and reagent preparation
Glassware sterilization
Biohazard waste processing
Clinical equipment sterilization
Labmate LMDA-B104 operates through a controlled sterilization cycle:
Load materials into the chamber
Seal the stainless steel chamber
Select digital sterilization program
Generate high-pressure steam
Maintain temperature for set time
Depressurize and cool safely
Steam provides efficient heat transfer and penetrates materials effectively, allowing microbial destruction at controlled temperatures and pressures.
Pharmaceutical laboratories
Biotechnology facilities
Hospitals and clinical departments
Research and academic institutions
Food and environmental testing labs
Temperature: 105–134°C
Pressure: 0.1–0.25 MPa
Cycle Time: 0–120 minutes
Capacity: 60 L
Monitoring: Digital interface
Heat-sensitive plastics
Volatile or flammable chemicals
Sealed containers
Electronic devices
Labmate LMDA-B104 is suitable for laboratories that require sterilization of medium to large loads with consistent cycle control and digital monitoring.
Large 60 L chamber capacity
Programmable sterilization cycles
Digital monitoring system
Stainless steel chamber durability
Safety interlocks and pressure control
Digital cycle programming
Steam sterilization for lab materials
Real-time parameter monitoring
Safety protection systems
Sterilization is confirmed using biological indicators, chemical indicators, and continuous monitoring of temperature, pressure, and time cycles.
Avoid overloading chamber
Use heat-resistant handling tools
Ensure proper ventilation
Follow laboratory SOPs
Smaller digital autoclaves for low-volume labs
Vertical autoclaves for flexible loading
Industrial steam sterilizers for high-capacity use
Compared to LMDA-B101 and LMDA-B102P, LMDA-B104 provides the largest chamber capacity (60 L), making it suitable for high-volume sterilization workflows in laboratories and hospitals.
Q1. What is Labmate LMDA-B104 used for?
It sterilizes laboratory instruments and materials using high-pressure steam.
Q2. How long is a cycle?
Between 15 and 120 minutes depending on load.
Q3. What is the chamber size?
60 liters.
Q4. Can it sterilize liquids?
Yes, with appropriate programmed cycles.
Q5. Is it suitable for hospitals and labs?
Yes, it is used in clinical, pharmaceutical, and research environments.