Get Quote
Contact us now to receive a detailed quotation.
A high-pressure steam autoclave is a laboratory sterilization device that uses pressurized steam at 105°C–134°C to destroy microorganisms, bacteria, viruses, and spores on laboratory materials.
Labmate LMHPA-A100 is used to sterilize laboratory instruments, glassware, liquids, textiles, and consumables using controlled high-pressure steam cycles.
It is commonly used in:
Pharmaceutical laboratories
Hospitals and clinical facilities
Research and biotechnology labs
Food and microbiology testing labs
Sterilization method: High-pressure steam
Temperature range: 105°C–134°C
Chamber capacity: 120 L
Cycle time: 20–60 minutes
Applications: Instruments, media, glassware, lab consumables
Steam sterilization removes microorganisms by applying heat under pressure, making laboratory materials safe for medical, research, and production use.
Labmate LMHPA-A100 uses controlled steam pressure to sterilize materials inside a sealed chamber.
Load materials into chamber
Steam raises temperature and pressure
Heat penetrates all surfaces
Microorganisms and spores are destroyed
Pressure is released safely
Materials are cooled and removed
121°C is used for standard sterilization cycles
134°C is used for fast or high-load sterilization
Yes. The system uses controlled heating cycles to sterilize liquids and culture media without boiling over.
Programmable sterilization cycles
Digital temperature and pressure monitoring
Stainless steel chamber construction
Safety interlock system
Compact laboratory design
The sterilizer includes:
Overpressure protection
Door locking during operation
Emergency shutdown system
Controlled pressure release mechanism
Use this sterilizer when:
Medium-scale laboratory sterilization is required
Controlled cycle programming is needed
ISO and GMP compliance is necessary
Space-efficient benchtop sterilization is preferred
An autoclave is a type of steam sterilizer that uses pressurized steam to sterilize materials, while digital models add programmable control and cycle monitoring.
Sterilization of surgical instruments
Preparation of culture media
Glassware sterilization
Laboratory consumables processing
Sterilization effectiveness is confirmed using:
Biological indicators (spore tests)
Chemical indicators
Monitoring temperature, pressure, and time cycles
ISO 17665: Defines validation rules for steam sterilization
GLP: Ensures structured laboratory practices
GMP: Ensures quality in pharmaceutical processes
Choose LMHPA-A100 for compact 120 L sterilization needs
Choose higher models for larger batch volumes
Selection depends on workflow size and frequency
It sterilizes instruments, liquids, glassware, and lab consumables.
Typical cycles range from 20 to 60 minutes depending on load type.
Yes, controlled steam cycles prevent overflow and overheating.
Heat-sensitive plastics, sealed containers, and volatile chemicals.
Yes, it supports ISO and GMP sterilization workflows.