Anaerobic Incubation Jar LMAJ-C100 For Batch Culture Processing


What Is a Labmate LMAJ-C100 Anaerobic Jar?

Labmate LMAJ-C100 is a sealed laboratory container used to create oxygen-free or oxygen-reduced conditions for incubating anaerobic microorganisms inside standard laboratory incubators.

Quick Answer Summary

  • Creates oxygen-free environment for microbial incubation

  • Uses gas sachets or external gas input

  • Holds multiple Petri dishes in sealed chamber

  • Includes oxygen indicator for confirmation

  • Used in clinical, pharmaceutical, academic, and research labs

Product Snapshot

Attribute

Details

Product Name

Anaerobic Jar

Model Number

LMAJ-C100

Product Type

Oxygen-Controlled Incubation Container

Used For

Anaerobic microbial culture

Industries

Clinical, pharma, biotech, academic, environmental

Capacity

Multiple Petri dishes

Atmosphere

Gas sachet / external gas

Warranty

1 Year

What Is This Product Used For?

Labmate LMAJ-C100 is used to incubate anaerobic microorganisms under oxygen-free conditions for microbiological testing and research.

Common applications:

  • Clinical anaerobic bacterial isolation

  • Antibiotic susceptibility testing

  • Pharmaceutical microbial testing

  • Gut microbiome research

  • Environmental microbial studies

  • Academic microbiology training

How Does Labmate LMAJ-C100 Work?

Labmate jar creates anaerobic conditions by sealing culture plates and removing oxygen using gas-generating systems or controlled gas input.

Step-by-step:

  1. Plates placed inside sealed jar

  2. Gas sachet or gas input activated

  3. Oxygen removed or reduced

  4. Oxygen indicator confirms condition

  5. Jar placed in incubator

Core Functional Capabilities

  • Oxygen-free sealed incubation

  • Multi-plate processing capacity

  • Gas sachet compatibility

  • Oxygen indicator validation

  • Transparent chamber for visibility

  • Incubator-compatible format

Technical Specifications

Parameter

Specification

Atmosphere

Gas sachet / external gas

Material

Laboratory-grade polycarbonate

Seal

Clamp or locking lid

Capacity

Multiple 90 mm Petri dishes

Indicator

Oxygen strip

Use Environment

Clinical, pharma, research labs

Where Is Labmate LMAJ-C100 Used?

  • Hospital microbiology laboratories

  • Pharmaceutical QC laboratories

  • Biotechnology research labs

  • Academic institutions

  • Environmental testing labs

  • Public health laboratories

When Should You Use Labmate LMAJ-C100?

Use this jar when:

  • Batch anaerobic incubation is required

  • Multiple samples must be processed together

  • Compact incubator-compatible system is needed

  • Routine microbiology testing is performed

  • Cost-efficient anaerobic setup is preferred

When NOT to Use This Product

Avoid this system when:

  • Continuous sample handling is required → use anaerobic chamber

  • Large workstation-style handling is needed

  • Real-time atmospheric adjustment is required

  • Complex gas control workflows are necessary

Anaerobic Jar vs Alternatives

System

Use Case

Atmosphere Control

Scale

LMAJ-C100

Batch incubation

Gas sachet / gas input

Medium

Anaerobic Chamber

Continuous handling

N₂/H₂/CO₂

Large

CO₂ Incubator

Capnophilic growth

CO₂ controlled

Medium


Key Concepts Explained

1. What Are Anaerobic Conditions?

    An oxygen-free environment required for growth of specific microorganisms.

2. What Is a Gas Sachet System?

    A chemical system that removes oxygen and generates gases inside a sealed jar.

3. What Is an Oxygen Indicator?

    A colour-changing strip that confirms absence of oxygen inside the chamber.

Typical Applications

  • Clinical pathogen isolation

  • Pharmaceutical microbial testing

  • Microbiome research

  • Environmental microbiology

  • Academic laboratory training

Compliance and Laboratory Alignment

Supports:

  • GLP (Good Laboratory Practice)

  • GMP (Good Manufacturing Practice)

  • Standard microbiology protocols

Frequently Asked Questions 

Q1. What does an anaerobic jar do?

      It creates a sealed oxygen-free environment for microbial growth.

Q2. How are anaerobic conditions created?

       Using gas sachets or controlled gas injection inside a sealed jar.

Q3. How long does it take to create anaerobic conditions?

      Typically 15–30 minutes depending on system setup.

Q4. How is oxygen absence confirmed?

      Through an oxygen indicator strip inside the jar.

Q5. Can it be used in hospitals?

       Yes, it is widely used in clinical microbiology laboratories.

Q6. Is it reusable?

       Yes, the jar is reusable; sachets and indicators are consumables.

Q7. What is the difference between jar and chamber?

       Jar: Used for batch incubation of samples.
      Chamber: Designed to provide a controlled environment for continuous handling and manipulation

Q8. How many plates can it hold?

       Multiple standard Petri dishes depending on configuration.

Internal Linking Opportunities

  • Anaerobic Jars

  • Anaerobic Chambers

  • CO₂ Incubators

  • Microbial Cultivation Guide

  • Laboratory Incubation Systems

Quick Summary

Labmate LMAJ-C100 is a sealed anaerobic incubation container used for oxygen-free microbial culture. It supports batch processing, incubator compatibility, and controlled atmospheric conditions for clinical, pharmaceutical, and research laboratories.