Portable Multiparameter Water Quality Meter LMWM-701 is equipped with a backlit LCD display. It is suitable for measuring the PH, ORP, ion concentration, TDS, salinity, conductivity, resistivity, and dissolved oxygen. Automatic electrode recognition shows the pH slope and offset. Relative and absolute millivolt modes provide reliable ORP measurements. Data can be transferred easily to computer by using USB interphase. It is reliable, user friendly, applicable for outdoor measurements.
$1,440.00
pH Range: -2.000 to 20.000 pH
Specifications
pH Range | -2.000 to 20.000 pH |
pH Resolution | 0.001, 0.01, 0.1 pH, selectable |
pH Accuracy | ± 0.002 pH |
pH Calibration Points | 1 to 5 points |
pH Buffer Options | USA, NIST, DIN, 2 custom buffers |
ORP Range | ± 1999.9mV |
ORP Resolution | 0.1, 1mV, selectable |
ORP Accuracy | ± 0.2 mV |
ORP Calibration Points | 1 point |
ORP Measurement Modes | Relative or absolute mV |
Ion Concentration Range | 0.001 to 19999 (depending on the range of ISE) |
Ion Concentration Resolution | 0.001, 0.01, 0.1, 1 |
Ion Concentration Accuracy | ± 0.5% F.S. (monovalent), ±1% F.S. (divalent) |
Ion Calibration | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 |
Measurement Units | ppm, mg/L, ml/L, mml/L |
Conductivity Range | 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Conductivity Resolution | 0.001, 0.01, 0.1, 1 |
Conductivity Accuracy | ± 0.5% F.S. |
Conductivity Calibration | 1 to 5 points |
Conductivity Calibration Solutions | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
Conductivity Temperature Coefficient | Linear (0.0 to 10.0%/°C), pure water |
Conductivity Reference Temperature | 20/25°C |
Conductivity Cell Constant | K=0.1, 1, 10 or custom |
TDS Range | 0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
TDS Resolution | 0.01, 0.1, 1 |
TDS Accuracy | ±1% F.S. |
TDS Factor | 0.1 to 1.0 (default 0.5) |
Salinity Range | 0.00 to 80.00ppt, 0.00 to 42.00psu |
Salinity Resolution | 0.01 |
Salinity Accuracy | ±1% F.S. |
Resistivity Range | 0.00 to 20.00MΩ |
Resistivity Resolution | 0.01,0.1 |
Resistivity Accuracy | ±1% F.S. |
DO Range | 0.00 to 20.00 mg/L |
Dissolved Oxygen Resolution | 0.01mg/L, 0.1% |
Dissolved Oxygen Accuracy | ±0.2mg/L, ±2.0% |
DO Calibration | 1 or 2 points |
% Saturation of Oxygen | 0.00 to 20.00mg/L, 0.0 to 200.0% saturation |
Pressure Correction | 60.0 to 112.5 kPa/450~850mmHg, manual |
Salinity Correction | 0.0 to 50.0ppt, manual |
Temperature Compensation | 0 to 100°C/32 to 212 °F, manual or automatic |
Memory | 500 data sets, USB communication interface |
Power | 3 × 1.5V AA batteries or 5V DC power adapter |
Dimensions(L × W × H) | 170 × 85 × 30 mm |
Weight | 300 g |
Features
It can store and recall up-to 500 sets of dataApplications
It is widely used for quality testing of water and used in research and development laboratories and water resources.