Model No: AAS-009
|


|
|
Main Specification
|
Wavelength Range
|
190-900nm
|
|
|
Wavelength Accuracy
|
±0.5nm
|
|
|
Resolution
|
Better than 0.3nm
|
|
|
Baseline Stability
|
0.005A/30min
|
|
|
Light Source System
|
Lamp Turret
|
Automatic 8×2-lamp turrets (Two high performance hollow cathode lamps can
be mounted on each turret );
|
|
|
Lamp Current
|
0~15mA
|
|
|
Lamp Power Supply Mode
|
200Hz square wave pulse
|
|
|
Optical System
|
Monochomator
|
Czerny-Turner type Double Beam
|
|
|
Grating
|
1800 l/mm
|
|
|
Focal Length
|
430mm
|
|
|
Blazed Wavelength
|
250nm
|
|
|
Spectral Bandwidth
|
Fame mode: 0.2, 0.4, 0.8, 1.6mm
Graphite furnace mode: 0.2, 0.4, 1.2mm
|
|
|
Atomizer
|
Flame Atomizer
|
Burner: 10cm single slot all-titanium burner
Spray chamber: directly formed and made of corrosion resistant material.
Nebulizer: High efficiency glass nebulizer with metal sleeve.
Position adjustment: flame height is adjustable.
|
|
|
|
|
|
Graphite Furnace Atomizer
|
Temperature range: room temperature~3000°C
Heating rate: 3000°C/s
Graphite tube dimensions: 30mm(L) X 7mm (OD)
|
|
|
Graphite Furnace
|
Sample Tray Capacity
|
55 sample vessels and 5 reagent vessels
|
|
|
Autosampler
|
Vessel Material
|
Polypropylene
|
|
|
|
Vessel Volume
|
2ml for sample vessel, 20ml for reagent vessel
|
|
|
Minimum Sampling Volume
|
1µl
|
|
|
Repeatable Sampling Times
|
1~99 times
|
|
|
Sampling System
|
Accurate dual pump system, with 100?l and 1ml injectors.
|
|
|
Detection and Data
|
Detector
|
R955 Photomultiplier with high sensitivity and wide spectral range
|
|
|
Processing System
|
Software
|
Professional AAS software under Windows XP operating system
|
|
|
|
Analytical Method
|
Working curve auto-fitting; standard addition method automatic sensitivity
correction; automatic calculation of concentration and content.
|
|
|
Repeat times
|
1~99 times, automatic calculation of mean value, standard deviation and
relative standard deviation.
|
|
|
Multi-task Functions
|
Sequential determination of multi-elements in the same sample
|
|
|
Condition Reading
|
With model function
|
|
|
Result Printing
|
Measurement data and final analytical report print out, editing with Excel.
|
|
|
Communication
|
Standard RS-232 serial port; supporting USB port communication
|
|
|
Background correction System
|
Flame constant magnetic field Zeeman
|
|
|
|
background correction
|
Magnetic flux density: 1.0T
|
|
|
Graphite furnace constant magnetic field
|
|
|
|
Zeeman background correction
|
Magnetic flux density: 1.0T
|
|
|
Dimensions (LxWxH) mm3
|
Main unit:
|
1160 × 630 x 570
|
|
|
Auto-sampler:
|
320 x 270 x 260
|
|
|
Weights
|
Main unit:
|
160Kg
|
|
Auto-sampler:
|
15Kg
|
|