Model No: AAS-007
|


|
|
Main Specification
|
Wavelength Range
|
190-900nm
|
|
Wavelength Accuracy
|
Better than ±0.25nm
|
|
Resolution
|
Two spectral lines of Mn at 279.5nm and 279.8nm can be energy separated with the spectral bandwidth of 0.2nm and valley- peak ratio less than 30%
|
|
Baseline Stability
|
0.004A/30min
|
|
D2 lamp Background Correction
|
1A is better than 30 times
|
|
S-H Background Correction
|
1.8A better than 30 times
|
|
Light Source System
|
Lamp Turret
|
Motorized 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.);
|
|
Lamp Current Adjustment
|
Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA
|
|
Lamp Power Supply mode
|
400Hz square wave pulse;
100Hz narrow square wave pulse+400Hz wide square wave pulse
|
|
Optical System
|
Monochromator
|
Single beam, Czerny turner design grating monochromator
|
|
Grating
|
1800 l/mm
|
|
Focal Length
|
277mm
|
|
Blazed Wavelength
|
250nm
|
|
Spectral Bandwidth
|
0.1nm, 0.2nm, 0.4nm, 1.2nm auto-switch over
|
|
Flame Atomizer
|
Burner
|
10cm single slot all-titanium burner
|
|
Spray chamber
|
Corrosion resistant all-plastic spray chamber
|
|
Nebulizer
|
High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
|
|
Emission burner provided
|
|
|
Graphite Furnace
|
Temperature range
|
Room temperature~3000ºC
|
|
Heating rate
|
2000 ºC /s
|
|
Graphite tube dimensions
|
28mm(L)×8mm(OD)
|
|
Precision
|
Cd≤3%, Cu≤3%, Mo≤4%
|
|
Detection and Data Processing System
|
Detector
|
R928 Photomultiplier with high sensitivity and wide spectral range.
|
|
Software
|
Under Windows Operating System
|
|
Analytical Method
|
Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
|
|
Repeat Times
|
1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.
|
|
Multi-task Functions
|
Sequential measurement for multi-element determination to the same sample
|
|
Condition Reading
|
With model function
|
|
Result Printing
|
Measurement of Data and Final Analysis report printout, editing with Excel
|
|
Standard RS-232 serial port communication
|
|
Graphite Furnace Auto sample
|
Sample tray capacity
|
55 sample vessels and 5 reagent vessels
|
|
Vessel material
|
Polypropylene
|
|
Vessel volume
|
3ml for sample vessel, 20ml for reagent vessel
|
|
Minimum sampling volume
|
1μl
|
|
Repeatable sampling times
|
1 -99 times
|
|
Sampling system
|
Accurate dual pump system, with 100μl and 1ml injiectors
|
|
Characteristics Concentration and Detection Limit
|
Normal Air C2H2 Flame
|
Cu: Characteristic concentration≤0.025mg/L, Detection limit
≤0.006mg/L
|
|
Oxygen Rich Air C2H2Flame
|
Ba: Characteristic concentration≤ 0.22mg/L
|
|
Al: Characteristic concentration ≤ 0.4mg/L
|
|
Hydride Generation
|
Hg: detection limit≤0.5µg/L
|
|
Function Expansion
|
Hydride vapor generator can be connected for hydride analysis
|
|
Dimension
(L x W x H) mm and Weight
|
Main Unit
|
1070 (L) × 490 (W) × 580 (H)mm , 140kg
|
|
Graphite furnace
|
420×420×460mm, 65kg
|
|
Auto sampler
|
400×290×290mm, 15kg
|