The patented flame analysis technique adopting oxygen rich air acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analysis, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjusted between 2300-2950°C,which makes it possible to choose the best atomization temperature for different elements.
It features easy operation, low analysis cost.
Accurate automatic operation.
6-lamp turret automatic changeover, automatic adjustment of the lamp supply power, automatic optimize spectral beam position.
Automatic wavelength scanning and peaking.
Automatic spectral bandwidth selection.
Automatic igniting.
Perfect safety protection measures: Alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction.
Adopting large-scale programmable logic array and inter IC bus technology with advanced electronic design.
AMP adapters with high reliability to ensure long term reliability of the whole electric system.
Technical Specification:
Model No: AAS-006
Main Specification
WavelengthRange
190-900nm
Wavelength Accuracy
±0.5nm
Resolution
better than 0.3nm
Baseline Stability
0.005A/30min
Background Correction
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times
Hollow Cathode Lamps
Lamp Turret
4-lamp turret automatic changeover
Lamp Current Adjustment
Automatic adjustment and display.Wide pulse current: 0~25mA
Lamp Power Supply mode
400Hz square-wave pulses
Optical System
Monochromator
Single beam, Czerny-Turner design grating monochromator
Grating
1800 l/mm
Focal Length
277mm
Blazed Wavelength
250nm
Spectral Bandwidth
0.1nm, 0.2nm, 0.4nm, 1.2nm
Detection and Data Processing System
Detector
Photomultiplier with high sensitivity and wide spectral range
Software
Ms-WindowsTM operating system
Analytical Method
Working Curve Method (1st order and 2nd order fitting), Standard addition method
Repeatable Measurement
Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation
Condition Reading
With model function
Result Printing
Measurement of data and final analytical report printout
Flame Analysis
Burner
10cm single slot all titanium burner for Air-C2H2flame
Spray Chamber
All plastic spray chamber
Nebulizer
High efficiency glass nebulizer with metal sleeve
Position Adjustment
Adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner
Protection of Gas System
Fuel gas leak protection, abnormal flame extinction alarm, air-pressure deficiency protection and explosion proof device