Spectrophotometer


Atomic Absorption Spectrophotometer


  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A better than 30 times.
  • Lamp Turret– 6
  • Al: Characteristic concentration ≤ 0.4mg/L
     

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A better than 30 times.
  • Lamp Turret–6

  • Wavelength Range–190-900nm
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.
  • Lamp Turret–4

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame; 5cm single slot all titanium burner for     oxygen rich flame.

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– Automatic adjustment and display.Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–4.
  • Lamp Current Adjustment–Automatic adjustment and display.Wide pulse current: 0~25mA.
  • Burner–10cm single slot all titanium burner for Air-C2H2 flame.

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times.The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret– 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity)

  • Wavelength Range– 190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Number– 2 lamps (one preheating).
  • Burner– 10cm single slot all titanium burner.

  • Wavelength Range– 190-900nm.
  • Zeeman background correction technology
  • Lamp Turret– Automatic 8 x 2 lamp turret (Two high performance hollow cathode lamps can be mounted on       each turret)
  • Flame mode- 0.2, 0.4, 0.8, 1.6mm
  • Graphite furnace mode- 0.2, 0.4, 1.2mm

  • Wavelength Range– 190-900nm
  • Background Correction– Deuterium lamp 1.0 Abs
  • Burner– Titanium alloy burner

  • Wavelength Range–190-900nm.
  • Background Correction– The D2 lamp background correction capability at 1A is better than 30 times. The S-H    background correction capability at 1.8A is better than 30 times.
  • Lamp Turret–6.
  • Lamp Current Adjustment– 400Hz square wave pulse Wide pulse current: 0~25mA, Narrow pulse     current: 0~10mA.
  • Burner–10cm single slot all titanium burner.


Atomic Emission Spectrophotometer


  • Reasonable design and perfect performance.
  • Rapid analysis, perfect repeatability and stability.
  • High integrated data collection, control system and high automatic degree.
  • Used for many kinds of matrix analysis:Fe, Co, Ni, Ti, Cu, Al, Pb, Mg, Zn, Sn etc.
  • High repeatability & stability excitation source is adopted. Excitation frequency can change in 150 ~ 600 Hz range.


Atomic Fluorescence Spectrophotometer


  • Techniques with independent intellectual property.
  • Environmental protection type Atomic Fluorescence Spectrophotometer with "High efficiency Hg-elimination Technique" can decontaminate Hg pollution in lab environment efficiently and protect analyst’s health.
  • Determination of Hg, As, Sb, Bi, Se, Te, Pb, Sn, Ge, Zn and Cd.
  • Quartz atomizer with "full-ceramics infrared heating temperature control" technique has super long lifetime.
  • “Low-temperature atomic Argon-Hydrogen flame auto-ignition" can improve the analysis sensitivity of elements to be determined and reduce memory effect in large degree.


FTIR Spectrometers


  • Spectral Range – 7800cm-1 to 400cm-1
  • Resolution – Better than 0.85cm-1
  • Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
  • Detector – DTGS; Optional: MCT

  • Spectral Range – 7800cm-1 to 400cm-1
  • Resolution – Better than 0.5cm-1
  • Scanning Speed – 0.2 cm-1/s ~ 0.25cm-1/s automatically optimized for detector type or manually adjustable for specific application
  • Detector – DTGS; Optional: MCT


UV-Visible Double Beam Spectrophotometer


  • Optical System- Double Beam
  • Wavelength Range- 190 ~1100 nm
  • Spectral Bandwidth- 2 nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photo diode
  • Photometric Accuracy- ±0.3%T (0~100%T); ±0.002A (0~1A)
     

  • Optical System- Double Beam
  • Wavelength Range- 190~900nm
  • Spectral Bandwidth- 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm
  • Detector- Photomultiplier
  • Photometric Accuracy- ± 0.3%T (0~100%T), ± 0.002A
         (0~0.5A), ± 0.004A    (0.5A~1A)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (fixed slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)

  • Optical System- Double Beam
  • Wavelength Range- 190 - 900nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (Variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004 Abs (0.5 - 1A), ± 0.3%T (0 - 100%T)


UV-Visible Single Beam Spectrophotometer


  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 4nm, 1nm, 0.5nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- 0.3%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)

  • Optical System- Single Beam
  • Wavelength Range- 190 - 1100nm
  • Spectral Bandwidth- 2nm (5nm, 1nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T (0 - 100%T), 0.002A (0 - 0.5A), 0.004A (0.5A - 1A)


Visible Spectrophotometer


  • Optical System- Single Beam
  • Wavelength Range- 320 - 1100nm
  • Spectral Bandwidth- 2.0nm (5nm, 1nm optional)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.5%T (0 - 100%T), ± 0.002A (0 - 0.5A), ± 0.004A (0.5A - 1A)

  •  Wavelength Range- 320 ~ 1100nm
  • Spectral Bandwidth- 5nm (1nm, 2nm, 4nm optional)
  • Detector- Silicon photo-diode
  • Photometric Accuracy- 0.5%T
 

 



Visible Split Beam


  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 2nm fixed slit
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)

  • Optical System- Split Beam
  • Wavelength Range- 190-1100nm
  • Spectral Bandwidth- 0.5, 1, 2, 5nm (variable slit)
  • Detector- Silicon photodiode
  • Photometric Accuracy- ± 0.002Abs (0 - 0.5A), ± 0.004Abs (0.5 - 1A), ± 0.3%T(0 - 100%T)