Leave a Message
Leave a Message

Please fill out the form below and we will get back to you as soon as possible.

Laboratory Equipment

Labware

Variable Volume Pipettes

Variable Volume Pipette LMMP A200
Variable Volume Pipette LMMP A200
  • Autoclavable at 121 °C
  • Material: Polycarbonate
  • Available in 0.1 µL to 10000 µL volume
  • Ergonomic design provides excellent operating experience
  • Easy-to-read volume display
  • Trouble-free calibration and maintenance

Product Details
Variable Volume Pipette LMMP-A200

Volume Range : 0.1 - 2.5 μL
Increment : 0.05 μL
Error Value :

Test VolumeAccuracy errorPrecision error
2.5 μL
1.25 μL
0.25 μL
2.50 %
3.00 %
12.00 %
2.00 %
3.00 %
6.00 %

Variable Volume Pipette LMMP-A201

Volume Range : 0.5 - 10 μL
Increment : 0.1 μL
Error Value :

Test VolumeAccuracy errorPrecision error
10 μL
5 μL
1 μL
1.00 %
1.50 %
2.50 %
0.80 %
1.50 %
1.50 %

Variable Volume Pipette LMMP-A202

Volume Range : 2 - 20 μL
Increment : 0.5 μL
Error Value :

Test VolumeAccuracy errorPrecision error
20 μL
10 μL
2 μL
0.90 %
1.20 %
3.00 %
0.40 %
1.00 %
2.00 %

Variable Volume Pipette LMMP-A203

Volume Range : 5 - 50 μL
Increment : 0.5 μL
Error Value :

Test VolumeAccuracy errorPrecision error
50 μL
25 μL
5 μL
0.60 %
0.90 %
2.00 %
0.30 %
0.60 %
2.00 %

Variable Volume Pipette LMMP-A204

Volume Range : 10 - 100 μL
Increment : 1 μL
Error Value :

Test VolumeAccuracy errorPrecision error
100 μL
50 μL
10 μL
0.80 %
1.00 %
3.00 %
0.15 %
0.40 %
1.50 %

Variable Volume Pipette LMMP-A205

Volume Range : 20 - 200 μL
Increment : 1 μL
Error Value :

Test VolumeAccuracy errorPrecision error
200 μL
100 μL
20 μL
0.60 %
0.80 %
3.00 %
0.15 %
0.30 %
1.0 %

Variable Volume Pipette LMMP-A206

Volume Range : 50 - 200μL
Increment : 1 μL
Error Value :

Test VolumeAccuracy errorPrecision error
200 μL
100 μL
50 μL
0.60 %
0.80 %
1.00 %
0.15 %
0.30 %
0.40 %

Variable Volume Pipette LMMP-A207

Volume Range : 100 - 1000μL
Increment : 5 μL
Error Value :

Test VolumeAccuracy errorPrecision error
1000 μL
500 μL
100 μL
0.60 %
0.70 %
2.00 %
0.20 %
0.25 %
0.70 %

Variable Volume Pipette LMMP-A208

Volume Range : 200 - 1000μL
Increment : 5 μL
Error Value :

Test VolumeAccuracy errorPrecision error
1000 μL
500 μL
200 μL
0.60 %
0.70 %
0.90 %
0.20 %
0.25 %
0.30 %

Variable Volume Pipette LMMP-A209

Volume Range : 1000 - 5000 μL
Increment : 50 μL
Error Value :

Test VolumeAccuracy errorPrecision error
5000 μL
2500 μL
1000 μL
0.50 %
0.60 %
0.70 %
0.15 %
0.30 %
0.30 %

Variable Volume Pipette LMMP-A210

Volume Range : 2 - 10 mL
Increment : 0.1 mL
Error Value :

Test VolumeAccuracy errorPrecision error
10 mL
5 mL
2 mL
0.60 %
1.20 %
3.00 %
0.20 %
0.30 %
0.60 %